Continuous Blood Viscosity Monitoring System for Cardiopulmonary Bypass Applications
Abstract:
This paper proposes an algorithm that estimates blood viscosity during cardiopulmonary bypass (CPB) and validates its application in clinical cases. The proposed algorithm involves adjustable parameters based on the oxygenator and fluid types and estimates blood viscosity based on pressure-flow characteristics of the fluid perfusing through the oxygenator. This novel nonlinear model requires four parameters that were derived by in vitro experiments. The results estimated by the proposed method were then compared with a conventional linear model to demonstrate the former's optimal curve fitting. The viscosity (ηe) estimated using the proposed algorithm and the viscosity (η) measured using a viscometer were compared for 20 patients who underwent mildly hypothermic CPB. The developed system was applied to ten patients, and ηe was recorded for comparisons with hematocrit and blood temperature. The residual sum of squares between the two curve fittings confirmed the significant difference, with p < 0.001. ηe and η showed a very strong correlation with R2 = 0.9537 and p < 0.001. Regarding the mean coefficient of determination for all cases, the hematocrit and temperature showed weak correlations at 0.33 ± 0.14 and 0.22 ± 0.21, respectively. For CPB measurements of all cases, ηe was more than 98% distributed in the range from 1 to 3 mPa⋅s. This new system for estimating viscosity may be useful for detecting various viscosity-related effects that may occur during CPB.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....