Related Experiment Video
Updated: Mar 14, 2026

Author Spotlight: A 3D Digital Model for the Diagnosis and Treatment of Pulmonary Nodules
Published on: May 19, 2023
Dose-Optimized Computed Tomography for Screening and Follow-Up of Solid Pulmonary Nodules in Obesity: A Phantom Study
Katharina Martini1, Borna K Barth1, Kai Higashigaito1
1Institute of Diagnostic and Interventional Radiology, University Hospital Zurich (CH), Zurich, Switzerland.
Abstract:
To determine the lowest CT radiation dose-level at maintained image-quality and high sensitivity for detection of pulmonary-nodules in obesity. Single-energy CT with tin-filtration was performed in a chest-phantom with solid pulmonary-nodules simulating over-weight and obesity. CTDIvol of the standard-protocol was 0.41 mGy, subsequent scans were obtained at 1/2 and 1/4 dose-levels. Images were reconstructed using FBP and advanced-modeled iterative reconstruction (ADMIRE). Noise, image-quality, and sensitivity for nodule-detection were assessed. Noise was significantly reduced with ADMIRE (standard-dose: 73%; 1/2 dose: 73%; 1/4 dose: 71.2%; p < 0.001) compared to FBP. Image-quality was diagnostic for all images reconstructed with ADMIRE5. Sensitivity for nodule-detection was 100% at 1/2 and 1/4 dose-level for the phantom simulating over-weight and 97.37% (1/2 dose-level) and 81.58% (1/4 dose-level) for the phantom simulating obesity using ADMIRE5. In conclusion, single-energy CT with tin-filtration and ADMIRE shows potential for dose reduction in a phantom experiment down to 0.1 mGy in over-weight and 0.21 mGy obese subjects, while image quality and sensitivity for detection of solid pulmonary nodules remains high.
More Related Videos
07:54Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
Published on: December 21, 2019
07:53Author Spotlight: Advancing 3D Modeling for Enhanced Diagnosis and Treatment of Pulmonary Nodules in Early-Stage Lung Cancer
Published on: October 13, 2023
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET