Related Experiment Video
Updated: Mar 14, 2026

Resolving Water, Proteins, and Lipids from In Vivo Confocal Raman Spectra of Stratum Corneum through a Chemometric Approach
Published on: September 26, 2019
Continuous Gradient Temperature Raman Spectroscopy of Oleic and Linoleic Acids from -100 to 50 °C
C Leigh Broadhurst1,2, Walter F Schmidt3, Moon S Kim3
1Environmental Microbiology and Food Safety Laboratory, U.S. Department of Agriculture Agricultural Research Service, Bldg. 161 Rm. 116, 10300 Baltimore Avenue, Beltsville, MD, 20705, USA. leigh.broadhurst@ars.usda.gov.
Abstract:
We analyzed the unsaturated fatty acids oleic (OA, 18:1n-9) and linoleic (LA, 18:2n-3), and a 3:1 LA:OA mixture from -100 to 50 °C with continuous gradient temperature Raman spectroscopy (GTRS). The 20 Mb three-dimensional data arrays with 0.2 °C increments and first/second derivatives allowed rapid, complete assignment of solid, liquid, and transition state vibrational modes. For OA, large spectral and line width changes occurred in the solid state γ to α transition near -4 °C, and the melt (13 °C) over a range of only 1 °C. For LA, major intensity reductions from 200 to 1750 cm-1 and some peak shifts marked one solid state phase transition at -50 °C. A second solid state transition (-33 °C) had minor spectral changes. Large spectral and line width changes occurred at the melt transition (-7 °C) over a narrow temperature range. For both molecules, melting initiates at the diene structure, then progresses towards the ends. In the 3:1 LA:OA mixture, some less intense and lower frequencies present in the individual lipids are weaker or absent. For example, modes assignable to C8 rocking, C9H-C10H wagging, C10H-C11H wagging, and CH3 rocking are present in OA but absent in LA:OA. Our data quantify the concept of lipid premelting and identify the flexible structures within OA and LA, which have characteristic vibrational modes beginning at cryogenic temperatures.
More Related Videos
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...
Spectroscopy of Carboxylic Acid Derivatives
IR and UV–Vis Spectroscopy of Aldehydes and Ketones
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to...

