Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
A physics based approach to the pulse wave velocity prediction in compliant arterial segments
Alexander S Liberson1, Jeffrey S Lillie1, Steven W Day1
1Rochester Institute of Technology, James E. Gleason Building, 76 Lomb Memorial Drive, Rochester, NY 14623-5604, United States.
Abstract:
Pulse wave velocity (PWV) quantification commonly serves as a highly robust prognostic parameter being used in a preventative cardiovascular therapy. Being dependent on arterial elastance, it can serve as a marker of cardiovascular risk. Since it is influenced by a blood pressure (BP), the pertaining theory can lay the foundation in developing a technique for noninvasive blood pressure measurement. Previous studies have reported application of PWV, measured noninvasively, for both the estimation of arterial compliance and blood pressure, based on simplified physical or statistical models. A new theoretical model for pulse wave propagation in a compliant arterial segment is presented within the framework of pseudo-elastic deformation of biological tissue undergoing finite deformation. An essential ingredient is the dependence of results on nonlinear aspects of the model: convective fluid phenomena, hyperelastic constitutive relation, large deformation and a longitudinal pre-stress load. An exact analytical solution for PWV is presented as a function of pressure, flow and pseudo-elastic orthotropic parameters. Results from our model are compared with published in-vivo PWV measurements under diverse physiological conditions. Contributions of each of the nonlinearities are analyzed. It was found that the totally nonlinear model achieves the best match with the experimental data. To retrieve individual vascular information of a patient, the inverse problem of hemodynamics is presented, calculating local orthotropic hyperelastic properties of the arterial wall. The proposed technique can be used for non-invasive assessment of arterial elastance, and blood pressure using direct measurement of PWV, with account of hyperelastic orthotropic properties.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse
The pulse serves as a clinical...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Velocity and Acceleration of a Wave
The velocity of the particles can be obtained by taking the partial derivative of the position equation with respect to time....
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...