Related Experiment Video
Updated: Mar 14, 2026

Esophageal Heat Transfer for Patient Temperature Control and Targeted Temperature Management
Published on: November 21, 2017
Accuracy of the Distress Thermometer for home care patients with palliative care needs in Germany
Johannes Wüller1, Stefanie Küttner2, Ann Christina Foldenauer3
1Home Care Städteregion Aachen,Aachen,Germany.
Objective:
Our aim was to examine the accuracy of the German version of the Distress Thermometer (DT) compared with the Hospital Anxiety and Depression Scale (HADS) in patients with palliative care needs living at home.
Method:
Ours was a 15-month cross-sectional study beginning in September of 2013 in Germany with consecutive patients cared for by a palliative home care service. The survey was implemented during the initial visit by a home care team. Patients were excluded if they were under 18 years of age, mentally or physically unable to complete the assessment questionnaires as judged by their healthcare worker, or unable to understand the German language. During the first encounter, the DT and HADS were applied, and sociodemographic and medical data were collected.
Results:
A total of 89 persons completed both the HADS and DT questionnaires (response rate = 59.7%; mean age = 67 years; female = 55.1%; married = 65.2%; living home with relatives = 73.0%; oncological condition = 92.1%; Karnofsky Performance Scale [KPS] score: 0-40 = 30.3%, 50-70 = 57.3%, >80 = 6.7%). The mean DT score was 6.3 (±2.3), with 84.3% of participants scoring above the DT cutoff (≥4). The mean HADStotal score was 17.9 (±7.8), where 64% of participants had a total HADS score (HADStotal) ≥15, 51.7% reported anxiety (HADSanxiety ≥ 8), and 73% reported depression (HADSdepression ≥ 8). Using the HADS as a gold standard, a DT cutoff score ≥5 was optimal for identifying severe distress in patients with palliative care needs, with a sensitivity of 93.0%, a specificity of 34.4%, a positive predictive value (PPV) of 73.3%, and likelihood ratios LR+ = 1.42 (<3) and -LR = 0.203 (<0.3).
Significance Of Results:
The DT performed satisfactorily compared to the HADS in screening for distress in our study and can be employed as an instrument for identification of patients with distress. Consequent to the high prevalence of distress, we recommend its routine use for screening distressed persons at home with palliative care needs in order to offer adequate support.
More Related Videos
08:22Using an Ingestible Telemetric Temperature Pill to Assess Gastrointestinal Temperature During Exercise
Published on: October 7, 2015
04:34Mouse Body Temperature Measurement Using Infrared Thermometer During Passive Systemic Anaphylaxis and Food Allergy Evaluation
Published on: September 14, 2018
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...