Gateway-Assisted Retransmission for Lightweight and Reliable IoT Communications

Hui-Ling Chang1, Cheng-Gang Wang2, Mong-Ting Wu3

  • 1Department of Computer Science and Information Engineering, National Cheng Kung University, Tainan 701, Taiwan. momo@imslab.csie.ncku.edu.tw.

Sensors (Basel, Switzerland)
|September 27, 2016
PubMed

Related Concept Videos

IP3/DAG Signaling Pathway01:11

IP3/DAG Signaling Pathway

Membrane lipids such as phosphatidylinositol (PI) are precursors for several membrane-bound and soluble second messengers. Specific kinases phosphorylate PI and produce phosphorylated inositol phospholipids. One such inositol phospholipids are the  phosphatidylinositol-4,5 bisphosphate [PI(4,5)P2], present in the inner half of the lipid bilayer. Upon ligand binding, GPCR stimulates Gq proteins to turn on phospholipase Cꞵ. Activated phospholipase Cꞵ cleaves PI(4,5)P2 and...
14.1K
Pilot and Numeric Relaying01:21

Pilot and Numeric Relaying

Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying:
449
Carrier-Mediated Transport01:06

Carrier-Mediated Transport

Carrier-mediated transport is a pivotal process in drug absorption, particularly for lipid-insoluble drugs, and encompasses facilitated diffusion and active transport. Facilitated diffusion allows drugs to move along their concentration gradient without energy expenditure, while active transport utilizes ATP to drive drug movement against this gradient.
Active transport involves two types of membrane-spanning transporters: uptake and efflux. Uptake transporters are expressed in the small...
952
Maximum Power Transfer01:16

Maximum Power Transfer

Numerous practical applications within engineering disciplines, such as telecommunications, necessitate optimizing power delivery to a connected load. This pursuit, however, entails inherent internal losses, which can either equal or exceed the power supplied to the load. The Thevenin equivalent circuit is helpful in finding the maximum power a linear circuit can deliver to a load. It is assumed in this context that the load resistance can be adjusted.
By substituting the entire circuit with...
774
Distribution Reliability and Automation01:25

Distribution Reliability and Automation

Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
460