l-α-Phosphatidylglycerol Chlorohydrins as Potential Biomarkers for Chlorine Gas Exposure
Related Experiment Video
Updated: Mar 14, 2026

In vitro Cell Culture Model for Toxic Inhaled Chemical Testing
Published on: May 8, 2014
Petrus Hemström1, Andreas Larsson1, Linda Elfsmark1
1The Swedish Defense Research Agency, FOI CBRN Defense and Security, 90182 Umeå, Sweden.
Abstract:
Chlorine is a widely available toxic chemical that has been repeatedly used in armed conflict globally. The Organization for the Prohibition of Chemical Weapons (OPCW) have on numerous occasions found "compelling confirmation" that chlorine gas has been used against civilians in northern Syria. However, currently, there are no analytical methods available to unambiguously prove chlorine gas exposure. In this study, we describe the screening for chlorinated biomolecules by the use of mass isotope ratio filters followed by the identification of two biomarkers present in bronchoalveolar lavage fluid (BALF) from chlorine gas exposed mice. The relevance of these markers for human exposure was verified by their presence in in vitro chlorinated human BALF. The biomarkers were detectable for 72 h after exposure and were absent in nonexposed control animals. Furthermore, the biomarkers were not detected in humans diagnosed with chronic respiratory diseases. The potential chlorine specific markers were all chlorohydrins of unsaturated pulmonary surfactant phospholipids; phosphatidylglycerols, and phosphatidylcholines. Mass spectrometry fragmentation characteristics were favorable for the phosphatidylglycerol chlorohydrins, and they were therefore proposed as the best biomarker candidates.
More Related Videos
14:22Free Radicals in Chemical Biology: from Chemical Behavior to Biomarker Development
Published on: April 15, 2013
10:31A Liposome Membrane Permeability Assay for Investigating the Effects of Phosphatidylinositol Phosphate Groups on Membranotropic Action of Venom PLA2
Published on: September 26, 2025
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Mass Spectrometry: Alkyl Halide Fragmentation
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...