RENEW-a renal redesign project in predialysis patient care

Josephine Sau Fan Chow1, Kim Jobburn2, Margaret Chapman2

  • 1Clinical Innovation & Business Unit, South Western Sydney Local Health District, Clinical Stream Office, Liverpool Hospital,Reception Point 101, Clinical Building, Locked Bag 7103, BC1871, Liverpool, NSW 2170, Australia; University of Sydney, Sydney, NSW, Australia; University of Tasmania, Hobart, TAS, Australia.

Clinical Kidney Journal
|September 29, 2016
PubMed
Abstract

Related Concept Videos

Acute Kidney Injury V: Interprofessional Care01:20

Acute Kidney Injury V: Interprofessional Care

Acute Kidney Injury (AKI) requires a collaborative healthcare approach to restore renal function and prevent complications. Essential management strategies involve monitoring fluid and electrolyte balance, adjusting medications, initiating dialysis when necessary, and providing nutritional support.Fluid and Electrolyte ManagementFluid Monitoring: Regularly monitoring body weight, central venous pressure, and urine output helps detect fluid imbalances early. Patient intake and output are...
447
Continuous Renal Replacement Therapy01:30

Continuous Renal Replacement Therapy

Continuous Renal Replacement Therapy, also known as CRRT, is a procedural treatment for acute kidney injury (AKI) that gradually removes uremic toxins and fluids while maintaining acid-base balance and stabilizing electrolytes. It is particularly useful for hemodynamically unstable patients. Unlike intermittent hemodialysis, which is faster, CRRT provides a gentler approach over 24 hours, closely mimicking the function of natural kidneys. However, CRRT is not ideal for patients with...
1.6K
Hemodialysis III: Nursing Management01:25

Hemodialysis III: Nursing Management

The nursing management of a patient undergoing hemodialysis includes several critical steps, starting with a thorough assessment before the procedure.Before the Hemodialysis ProcedureFirst, record the patient's vital signs—blood pressure, heart rate, respiratory rate, and temperature—to establish a baseline. This baseline is essential for detecting conditions such as hypotension that could impact the patient's response to dialysis. Document the patient's pre-dialysis weight, as this...
1.3K
Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
1.5K
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy01:26

Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy

Continuous Renal Replacement Therapy (CRRT) is an essential intervention for patients experiencing severe kidney dysfunction. This therapy offers a continuous mechanism for removing fluids and toxins from the bloodstream, leveraging the patient’s blood pressure to facilitate filtration through a specialized filter. This method contrasts with intermittent dialysis, providing a gentler and more consistent removal of waste products and excess fluid, which is particularly beneficial in...
315
Peritoneal Dialysis III: Nursing Management01:25

Peritoneal Dialysis III: Nursing Management

Peritoneal dialysis, or PD, utilizes the peritoneal membrane as a filter to eliminate excess fluid and waste products. Effective nursing management is essential for ensuring patient safety, preventing complications, and promoting optimal function of the peritoneal dialysis process.Assessment and MonitoringNurses must thoroughly assess the patient before, during, and after each dialysis session. Regular monitoring includes vital signs, daily weight, fluid intake and output, and laboratory values...
1.2K