Blood Flow Imaging with Ultrafast Doppler
Published on: October 14, 2020
Influence of Pulse Repetition Frequency on 3-D Power Doppler Quantification
Carlos A M Soares1, Theo Z Pavan2, Andre H Miyague3
1Department of Obstetrics and Gynecology, Ribeirao Preto Medical School, University of Sao Paulo (DGO-FMRP-USP), Ribeirao Preto, Brazil.
Abstract:
Three-dimensional power Doppler quantification has limited application because of its high dependency on attenuation. The purpose of the study described here was to assess if different degrees of attenuation, depending on pulse repetition frequency (PRF) adjustment, alter 3-D power Doppler quantification in a region of 100% moving blood when using vascularization index, flow index and vascularization flow index (VFI). A cubic-shaped gelatin phantom with a 1.8-mm-internal-diameter silicon tube was used. The tube, placed at 45° to the phantom's surface, was filled with blood-mimicking fluid with as constant maximum velocity of 30 cm/s. Two different attenuation blocks (low and high attenuation) were alternatively placed between the phantom and the transvaginal transducer. One single observer acquired 10 data sets for each PRF level from 0.3 to 7.5 kHz, using the high- and low-attenuation blocks, for a total of 200 3-D power Doppler data sets. We assessed VFI from 1.5-mm-diameter spherical samples, virtually placed inside the tube, always at the same position. No difference was noted between high- and low-attenuation VFI values when using a PRF of 0.3 kHz. As PRF increased, it was observed that VFI quantification progressively differed between low and high attenuation. Also, a slope on VFI values for both high- and low-attenuation models could be observed when increasing PRF, particularly above 4.0 kHz. We concluded that PRF adjustment is very relevant when using VFI to quantify 3-D power Doppler signal.
More Related Videos
Related Concept Videos
Doppler Effect - II
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Doppler Effect - I
Special considerations while measuring pulse