Illicit Drugs in Oral Fluid: Evaluation of Two Collection Devices
Camille Cohier1,2,3,4, Bruno Mégarbane1,2,3,5, Olivier Roussel6,2,3,4
1Inserm "Variabilité de la Réponse aux Psychotropes", 4 Avenue de l'Observatoire, 75006 U1144, Paris, France.
Abstract:
Driving after illicit drug use is a worldwide growing concern requiring rapid and sensitive screening at the roadside. It is noteworthy that the sampling method used to collect oral fluid (OF) may significantly influence drug concentrations in the collected sample and thus alter the accuracy of the measurement. We evaluated two OF collection devices, Quantisal® and Certus® collectors, for their suitability for collecting samples to allow laboratory confirmation of driving after illicit drug use. Four parameters were studied including (i) the collected OF volume; (ii) the recovery efficiency using OFs spiked with opiates, cannabinoids, amphetamines, cocaine and its metabolites; (iii) drug stability after storage for 1, 7 and 14 days at -20°C, +4°C and room temperature; and (iv) the impact of mouth cells present in the collected OF on drug stability. Drug concentrations were measured using gas and liquid chromatography-mass spectrometry. Certus® collector allowed the collection of significantly larger (0.94 ± 0.18 mL vs. 0.84 ± 0.06 mL, P = 0.08) but less reproducible OF volumes (19 vs. 6.7%) compared with Quantisal® collector. Drug recovery was significantly better with Quantisal® than with Certus® collector, especially when used to detect cannabinoids (0.94 vs. 0.54, P < 0.001 for ∆9-tetrahydrocannabinol (THC)). For both OF collectors, storage at 4°C was preferable except for methadone, the stability of which was altered by adherence to the collector device. In the presence of mouth cells in the OF sample, THC concentrations were significantly decreased at Day 7 in comparison with Day 1 with both collection devices (P = 0.001 with Quantisal® collector and P = 0.01 with Certus® collector). In conclusion, Quantisal® collector is more reliable than Certus® collector although the practicability of both devices remains to be determined at the roadside.
Related Concept Videos
Drug Excretion: Pulmonary and Glandular Routes
Drugs can also be excreted in breast milk, which is crucial for breastfeeding infants. The...
In Vitro Drug Dissolution: Compendial Testing Models II
In Vitro Drug Dissolution: Alternative Methods
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...