Characteristics and variations of in vivo Schlemm's canal and collector channel microstructures in enhanced-depth
Pengcheng Li1,2, Anum Butt1, Jason L Chien1
1Moise and Chella Safra Advanced Ocular Imaging Laboratory, Einhorn Clinical Research Center, New York Eye and Ear Infirmary of Mount Sinai, New York, New York, USA.
Background/Aims:
To characterise in vivo Schlemm's canal (SC) and collector channels (CC) microstructures using enhanced-depth imaging (EDI) optical coherence tomography (OCT).
Methods:
Serial horizontal EDI OCT B-scans (81 scans, 15×5° rectangle) were prospectively obtained in the nasal and temporal limbus. SC cross-sectional area (CSA) was measured by delineating its lumen in each B-scan. CCs connected to SC were counted. SC CSA and the number of CCs were compared between the nasal and temporal areas.
Results:
Eleven eyes (11 normal subjects) were included (mean age, 28±5 years). SC and CCs were clearly demarcated in EDI OCT B-scans with excellent repeatability and reproducibility (intraclass correlation coefficients, 0.830-0.886 and 0.793, respectively; all p<0.001). SC CSA varied considerably among subjects, ranging from 1664 to 6007 µm2 (average, 3514±1235 µm2), and among different regions of the same eye with coefficient of variation in each eye ranging from 23% to 46% (average, 32±7%). The number of CCs in the analysed area also varied considerably among subjects, ranging from 5 to 11 (average, 8.73±1.85). The mean SC CSA (3839±1402 µm2 vs 3189±1209 µm2; p=0.033) and number of CCs (5.5±1.4 vs 3.3±1.1; p=0.001) were significantly greater nasally than temporally. The mean SC CSA was significantly correlated with the number of CCs (r=0.635, p=0.036).
Conclusions:
High-quality images of the aqueous outflow pathway can be obtained with a clinical device, avoiding postacquisition processing. In vivo SC and CC microstructures vary considerably among individuals and regions. SC tends to be larger in regions with more CCs.
More Related Videos
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Confocal Fluorescence Microscopy