Loop recorders for syncope evaluation: what is the evidence?
Christopher C Cheung1, Andrew D Krahn1
1a Heart Rhythm Vancouver, Division of Cardiology , University of British Columbia , Vancouver , BC , Canada.
Introduction:
Implantable loop recorders (ILRs) have become an important pillar in the diagnostic work-up of patients with unexplained syncope. Areas covered: The modern ILR is minimally-invasive and provides an extended-duration of monitoring with high diagnostic yield. These insertable cardiac monitors (ICMs) enable prolonged monitoring that extends the opportunity for symptom-rhythm correlation from days-weeks to years, with associated incremental diagnostic yield. Over the years, observational studies and randomized trials have supported a unique role for ILRs in the assessment of recurrent or high-risk unexplained syncope. Furthermore, ILRs have been used in the elderly, in children, patients with overt heart disease, and patients with conduction block with varying success. The current guidelines recommend ILRs in the early phase of evaluation in recurrent syncope, and as part of the comprehensive evaluation of high-risk patients with syncope. Expert commentary: In this review, we discuss the evidence surrounding ILRs, including comparison studies with 'conventional' management and the external loop recorder.
More Related Videos
14:09Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
10:07Simultaneous Recordings of Cortical Local Field Potentials, Electrocardiogram, Electromyogram, and Breathing Rhythm from a Freely Moving Rat
Published on: April 2, 2018
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring
Dysrhythmias V: Evaluating Dysrhythmias
Seizures: Classification
Seizures are typically classified into two main categories: focal and generalized seizures.
Focal Seizures
Focal seizures originate from specific regions of the brain. These seizures are further sub-classified into two types:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Dysrhythmias I: Introduction