Effect of cricoid pressure on laryngeal view during prehospital tracheal intubation: a propensity-based analysis
Emmanuel Caruana1,2, Sylvie Chevret1, Romain Pirracchio2,3,4
1Service Mobile d'Urgences et Réanimation, Hôpital Beaujon, Clichy, France.
Background:
The benefit of cricoid pressure during tracheal intubation is still debated and, due to its potential negative impact on laryngeal views, its routine use is questioned. The goal of this study was to estimate its impact on laryngeal view.
Methods:
All patients intubated in the prehospital setting were included. Three different propensity score (PS) models were used and compared in terms of the balance achieved between those patients who received cricoid pressure and those who did not. The PS model that optimised the balance was retained in order to estimate the relationship between cricoid pressure and the following outcomes: difficult laryngoscopy, intubation-related complications and difficult intubation.
Results:
Among the 1195 patients included, 499 (41.7%) received cricoid pressure. The optimal PS included seven variables (cardiac arrest, altered neurological status, shock, respiratory distress, gender, obesity, patient's position). After PS matching, no significant risk difference (RD) in the rate of difficult laryngoscopy was found between the patients who received cricoid pressure and those who did not (RD=0.001, 95% CI -0.07 to 0.08, p=0.50). No significant difference was found in terms of difficult intubation (RD=0.06, 95% CI -0.13 to 0.25, p=0.28) and in terms of prevalence of complications, except for airway trauma that were more frequent in cricoid pressure group (RD=0.03, 95% CI 0.002 to 0.05, p=0.01).
Conclusions:
No significant relationship was found between the use of cricoid pressure for prehospital intubation and difficult laryngoscopy. Cricoid pressure was found to be associated with more airway trauma. This finding could question its routine use.
Related Concept Videos
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of the...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques