Dynamic contrast-enhanced MRI measurement of renal function in healthy participants
Eli Eikefjord1,2, Erling Andersen1,3, Erlend Hodneland2,4
11 Department of Radiology, Haukeland University Hospital, Bergen, Norway.
Abstract:
Background High repeatability, accuracy, and precision for renal function measurements need to be achieved to establish renal dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) as a clinically useful diagnostic tool. Purpose To investigate the repeatability, accuracy, and precision of DCE-MRI measured renal perfusion and glomerular filtration rate (GFR) using iohexol-GFR as the reference method. Material and Methods Twenty healthy non-smoking volunteers underwent repeated DCE-MRI and an iohexol-GFR within a period of 10 days. Single-kidney (SK) MRI measurements of perfusion (blood flow, Fb) and filtration (GFR) were derived from parenchymal intensity time curves fitted to a two-compartment filtration model. The repeatability of the SK-MRI measurements was assessed using coefficient of variation (CV). Using iohexol-GFR as reference method, the accuracy of total MR-GFR was determined by mean difference (MD) and precision by limits of agreement (LoA). Results SK-Fb (MR1, 345 ± 84; MR2, 371 ± 103 mL/100 mL/min) and SK-GFR (MR1, 52 ± 14; MR2, 54 ± 10 mL/min/1.73 m2) measurements achieved a repeatability (CV) in the range of 15-22%. With reference to iohexol-GFR, MR-GFR was determined with a low mean difference but high LoA (MR1, MD 1.5 mL/min/1.73 m2, LoA [-42, 45]; MR2, MD 6.1 mL/min/1.73 m2, LoA [-26, 38]). Eighty percent and 90% of MR-GFR measurements were determined within ± 30% of the iohexol-GFR for MR1 and MR2, respectively. Conclusion Good repeatability of SK-MRI measurements and good agreement between MR-GFR and iohexol-GFR provide a high clinical potential of DCE-MRI for renal function assessment. A moderate precision in MR-derived estimates indicates that the method cannot yet be used in clinical routine.
Related Concept Videos
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Imaging Studies IV: Magnetic Resonance Imaging
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...