Related Experiment Video
Updated: Mar 14, 2026

Sound Source Localization Testing in Single-sided Deafness Following Bone Conduction Intervention
Published on: December 20, 2024
The Prediction of Speech Recognition in Noise With a Semi-Implantable Bone Conduction Hearing System by External Bone
Friedrich Ihler1, Jenny Blum1, Max-Ulrich Berger2
1Department of Otorhinolaryngology, University Medical Center Göttingen, Georg-August-University Göttingen, Germany.
Abstract:
Semi-implantable transcutaneous bone conduction devices are treatment options for conductive and mixed hearing loss (CHL/MHL). For counseling of patients, realistic simulation of the functional result is desirable. This study compared speech recognition in noise with a semi-implantable transcutaneous bone conduction device to external stimulation with a bone conduction device fixed by a headband. Eight German-language adult patients were enrolled after a semi-implantable transcutaneous bone conduction device (Bonebridge, Med-El) was implanted and fitted. Patients received a bone conduction device for external stimulation (Baha BP110, Cochlear) fixed by a headband for comparison. The main outcome measure was speech recognition in noise (Oldenburg Sentence Test). Pure-tone audiometry was performed and subjective benefit was assessed using the Glasgow Benefit Inventory and Abbreviated Profile of Hearing Aid Benefit questionnaires. Unaided, patients showed a mean signal-to-noise ratio threshold of 4.6 ± 4.2 dB S/N for speech recognition. The aided results were -3.3 ± 7.2 dB S/N by external bone conduction stimulation and -1.2 ± 4.0 dB S/N by the semi-implantable bone conduction device. The difference between the two devices was not statistically significant, while the difference was significant between unaided and aided situation for both devices. Both questionnaires for subjective benefit favored the semi-implantable device over external stimulation. We conclude that it is possible to simulate the result of speech recognition in noise with a semi-implantable transcutaneous bone conduction device by external stimulation. This should be part of preoperative counseling of patients with CHL/MHL before implantation of a bone conduction device.
More Related Videos
10:50Behavioral Determination of Stimulus Pair Discrimination of Auditory Acoustic and Electrical Stimuli Using a Classical Conditioning and Heart-rate Approach
Published on: June 6, 2012
06:27Simple Surgical Induction of Conductive Hearing Loss with Verification Using Otoscope Visualization and Behavioral Clap Startle Response in Rat
Published on: October 26, 2019