Related Experiment Video
Updated: Mar 14, 2026

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Breast Cancer Heterogeneity: MR Imaging Texture Analysis and Survival Outcomes
Jae-Hun Kim1, Eun Sook Ko1, Yaeji Lim1
1From the Departments of Radiology (J.H.K., E.S.K., K.S.L., B.K.H., E.Y.K., S.Y.H.) and Surgery (S.J.N.), Samsung Medical Center Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul 135-710, Korea; and Department of Statistics, Pukyong National University, Busan, Korea (Y.L.).
Abstract:
Purpose To determine the relationship between tumor heterogeneity assessed by means of magnetic resonance (MR) imaging texture analysis and survival outcomes in patients with primary breast cancer. Materials and Methods Between January and August 2010, texture analysis of the entire primary breast tumor in 203 patients was performed with T2-weighted and contrast material-enhanced T1-weighted subtraction MR imaging for preoperative staging. Histogram-based uniformity and entropy were calculated. To dichotomize texture parameters for survival analysis, the 10-fold cross-validation method was used to determine cutoff points in the receiver operating characteristic curve analysis. The Cox proportional hazards model and Kaplan-Meier analysis were used to determine the association of texture parameters and morphologic or volumetric information obtained at MR imaging or clinical-pathologic variables with recurrence-free survival (RFS). Results There were 26 events, including 22 recurrences (10 local-regional and 12 distant) and four deaths, with a mean follow-up time of 56.2 months. In multivariate analysis, a higher N stage (RFS hazard ratio, 11.15 [N3 stage]; P = .002, Bonferroni-adjusted α = .0167), triple-negative subtype (RFS hazard ratio, 16.91; P < .001, Bonferroni-adjusted α = .0167), high risk of T1 entropy (less than the cutoff values [mean, 5.057; range, 5.022-5.167], RFS hazard ratio, 4.55; P = .018), and T2 entropy (equal to or higher than the cutoff values [mean, 6.013; range, 6.004-6.035], RFS hazard ratio = 9.84; P = .001) were associated with worse outcomes. Conclusion Patients with breast cancers that appeared more heterogeneous on T2-weighted images (higher entropy) and those that appeared less heterogeneous on contrast-enhanced T1-weighted subtraction images (lower entropy) exhibited poorer RFS. © RSNA, 2016 Online supplemental material is available for this article.

