Related Experiment Video
Updated: Aug 11, 2026

Tear-Derived Exosomal miR-15a as New Diagnostic Tool for Diabetic Retinopathy
Published on: December 30, 2025
Comparison of Manual Refraction Versus Autorefraction in 60 Diabetic Retinopathy Patients
Keyvan Shirzadi1, Kourosh Shahraki2, Emad Yahaghi3
1Department of Ophthalmology, AJA University of Medical Sciences, Tehran, Iran.
Aim:
The purpose of the study was to evaluate the comparison of manual refraction versus autorefraction in diabetic retinopathy patients.
Material And Methods:
The study was conducted at the Be'sat Army Hospital from 2013-2015. In the present study differences between two common refractometry methods (manual refractometry and Auto refractometry) in diagnosis and follow up of retinopathy in patients affected with diabetes is investigated.
Results:
Our results showed that there is a significant difference in visual acuity score of patients between manual and auto refractometry. Despite this fact, spherical equivalent scores of two methods of refractometry did not show a significant statistical difference in the patients.
Conclusion:
Although use of manual refraction is comparable with autorefraction in evaluating spherical equivalent scores in diabetic patients affected with retinopathy, but in the case of visual acuity results from these two methods are not comparable.