Related Experiment Video
Updated: Mar 14, 2026

Assessment of Respiratory Function in Conscious Mice by Double-chamber Plethysmography
Published on: July 10, 2018
FeNO for detecting lower airway involvement in patients with allergic rhinitis
Zheng Zhu1, Yanqing Xie1, Weijie Guan1
1State Key Laboratory of Respiratory Disease, China Clinical Research Center of Respiratory Disease, First Affiliated Hospital of Guangzhou Medical University, Guangzhou, Guangdong 510120, P.R. China.
Abstract:
Allergic rhinitis (AR) is a risk factor for asthma development. The value of fractional exhaled nitric oxide (FeNO) in detecting lower airway involvement in the progress of AR-asthma march has not been evaluated. The aim of the present study was to investigate the value of FeNO in assessing lower airway inflammation and predicting bronchial hyperresponsiveness (BHR) in AR with or without asthma. FeNO and eosinophil count in induced sputum, and a methacholine bronchial provocation test were performed in 93 subjects, including: 45 AR patients (AR group); 20 patients with AR and asthma (AR with asthma group); and 28 normal controls (control group). The AR group was divided into two sub-groups: AR with asymptomatic BHR group and AR without BHR group. Correlation between FeNO and eosinophil count was assessed. Receiver operating characteristic (ROC) curve was applied to evaluate the predictive and diagnostic value of FeNO in detecting BHR. The values of FeNO in the AR and AR with asthma groups were higher [29.5 (22.0) ppb and 61.5 (33.0) ppb] compared with the normal control group (16.0 (10.0) ppb), where the values in brackets indicate the interquartile range of the values. The percentages of eosinophils in induced sputum were 2.43±3.56, 7.36±4.98 and 18.58±11.26% in the control, AR and AR with asthma groups, respectively. For the diagnosis of BHR, the area under the curve (AUC) was 0.910 (95%CI 0.836, 0.984), with the sensitivity and specificity 0.846 and 0.817 when the cut-off value takes 31.5 ppb. For diagnosis of asthma, the AUC was 0.873 (95%CI 0.753, 0.992) with sensitivity 0.857 and specificity 0.847 when taking the cut-off value to be 38.0 ppb. The value of FeNO was well correlated with eosinophil count in the sputum. The measurement of FeNO is an effective method in detecting lower airway involvement in AR developing to asthma.
Related Concept Videos
Physical Assessment of the Respiratory Tract II: Palpation
Thoracic Palpation
Thoracic palpation detects tenderness, masses, lesions, respiratory excursions, and vocal fremitus. The nurse assesses...
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
Asthma-IV: Diagnostic and Management
Clinical Assessment for Asthma:
This is the first step in diagnosing and managing asthma. It includes:
Drugs Used in Lower Respiratory Disorders: Overview
Bronchodilators, the first step of respiration enhancement, come in various forms, each with its own mechanism...
Physical Assessment of the Respiratory Tract I: Health History
Subjective Data
Subjective data provides vital information about the patient's health history and symptoms. This data is typically collected through interviews in which patients describe their experiences, symptoms, and concerns.
Health history and...
Physical Assessment of the Respiratory Tract IV: Auscultation
Breath Sounds
Breath sounds are categorized into vesicular, bronchovesicular, and bronchial.

