Related Experiment Video
Updated: Mar 14, 2026

Evaluation of a Point-of-Care Testing Analyzer for Measuring Peripheral Blood Leukocytes
Published on: March 22, 2022
Prevalence and Clinical Utility of "Incidental" Critical Values Resulting From Critical Care Laboratory Testing
Caleb V Grieme1, Dena R Voss1, Karin E Olson1
1Department of Pathology, University of Iowa Hospitals and Clinics, Iowa City, IA.
Objective:
Panels of clinical laboratory testing may generate "incidental" critical values from unordered parameters. Existing regulations do not clearly delineate guidelines for handling incidental critical values. The objective of this study was to examine the patterns and clinical utility of incidental critical values at 2 critical care laboratories within an academic medical center.
Methods:
In this retrospective study, the electronic health record and laboratory information system were reviewed for incidental critical results obtained from blood gas analyzer analysis of whole blood specimens between November 2010 and August 2014.
Results:
Within the retrospective time period, 9,092 incidental critical results were documented, of which only 11.8% were added to the "parent" order following clinical notification. Incidental critical results frequently occurred in patients who had recent critical values for the same parameter.
Conclusion:
In this study, at an academic medical center, incidental critical values associated with blood gas analyzers were added on at a low rate and often provided redundant information. Relative to the manual effort involved in care providers' notification and documentation of results, incidental critical values appear to have low clinical utility.
More Related Videos
10:38Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
11:17Multiplex Therapeutic Drug Monitoring by Isotope-dilution HPLC-MS/MS of Antibiotics in Critical Illnesses
Published on: August 30, 2018
Related Concept Videos
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Critical Values
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Acute Kidney Injury IV: Diagnostic Studies and Prevention
Pneumonia III: Complications and Assessment