Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Gas Chromatography–Mass Spectrometry (GC–MS)01:14

Gas Chromatography–Mass Spectrometry (GC–MS)

7.5K
Gas chromatography–mass spectrometry (GC–MS) is the combination of analytical techniques of gas chromatography and mass spectrometry in a single instrument for analyzing a mixture of compounds. The gas chromatograph separates the compounds in the mixture, and the mass spectrometer analyzes each compound separately to determine the molecular masses and molecular structures.
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
7.5K
Gas Chromatography: Introduction01:13

Gas Chromatography: Introduction

4.4K
Gas chromatography (GC) is a technique for separating and analyzing volatile compounds in a sample. Its primary purpose is to identify and quantify components in complex mixtures, making it essential in fields such as environmental analysis, pharmaceuticals, and petrochemicals. GC is also called vapor-phase chromatography (VPC) or gas-liquid partition chromatography (GLPC).
In GC,  a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
4.4K
Gas Chromatography: Overview of Detectors01:13

Gas Chromatography: Overview of Detectors

2.3K
Detectors in gas chromatography (GC) help identify and quantify the components of a mixture by translating chemical properties into measurable signals, which are displayed on a chromatogram. Detectors can be categorized into two main types: destructive and non-destructive.
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
2.3K
Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

1.4K
In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
1.4K
Gas Chromatography: Sample Injection Systems01:08

Gas Chromatography: Sample Injection Systems

1.8K
In gas chromatography, the sample is introduced as a vapor plug into the carrier gas stream for high efficiency and resolution. A microsyringe injects the sample solution into a heated sample port, vaporizing it and mixing it with the carrier gas. This process is important to ensure the sample is properly prepared for analysis. Thermally sensitive samples can be injected directly into the column and volatilized by slowly increasing the column temperature.
Two primary injection methods are used...
1.8K
Gas Chromatography: Types of Detectors-I01:21

Gas Chromatography: Types of Detectors-I

1.8K
There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
1.8K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

DGrA: Lightweight Modulation Recognition Based on Hybrid Neural Networks.

Sensors (Basel, Switzerland)·2026
Same author

Hardware-Agnostic Imitation Learning Method for Autonomous Ultrasound Scanning Addressing Physical Deployment Discrepancies.

Sensors (Basel, Switzerland)·2026
Same author

Comprehensive analysis suggests CRIF1 is a potential target in breast cancer associated with prognosis and immune infiltration.

Annals of medicine·2026
Same author

Ginsenoside Rb1-engineered nanocomposite hydrogel promotes pressure injury repair through SIRT1-AMPK-mediated ferroptosis inhibition and angiogenesis activation.

Journal of ginseng research·2026
Same author

Laser-based white-light source utilizing wavelength multiplexing for underwater high-speed wireless optical communication and high-fidelity illumination.

Optics express·2026
Same author

A Joint Framework of IMM-LSTM-C Tracking and IBPDO-Based Node Selection for Energy-Efficient Cooperative Tracking in Underwater Acoustic Sensor Networks.

Sensors (Basel, Switzerland)·2026

Related Experiment Video

Updated: Mar 14, 2026

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
10:14

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography

Published on: September 2, 2020

5.5K

Fully Automated Portable Comprehensive 2-Dimensional Gas Chromatography Device.

Jiwon Lee1,2, Menglian Zhou1,2, Hongbo Zhu1,2

  • 1Department of Biomedical Engineering, University of Michigan , 1101 Beal Avenue, Ann Arbor, Michigan 48109, United States.

Analytical Chemistry
|October 7, 2016
PubMed
Summary

A portable, automated 2-dimensional gas chromatography (GC x GC) device was developed. This compact system enhances separation capabilities and peak capacity for analyzing complex mixtures.

More Related Videos

Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
11:44

Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry

Published on: March 6, 2016

9.8K
Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
07:57

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector

Published on: July 25, 2014

20.5K

Related Experiment Videos

Last Updated: Mar 14, 2026

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
10:14

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography

Published on: September 2, 2020

5.5K
Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
11:44

Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry

Published on: March 6, 2016

9.8K
Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
07:57

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector

Published on: July 25, 2014

20.5K

Area of Science:

  • Analytical Chemistry
  • Chromatography
  • Instrumentation

Background:

  • Gas chromatography is a cornerstone of chemical analysis.
  • Traditional GC x GC systems are often large and complex.
  • There is a need for portable and automated GC x GC solutions.

Purpose of the Study:

  • To develop a fully automated, portable 2-dimensional gas chromatography (GC x GC) device.
  • To enhance the separation capabilities and peak capacity of GC x GC systems.
  • To demonstrate the system's performance in analyzing a mixture of diverse organic compounds.

Main Methods:

  • Development of a compact (60 cm × 50 cm × 10 cm, <5 kg) automated GC x GC device.
  • Integration of micropreconcentrator/injector, commercial columns, micro-Deans switches, and microphotoionization detectors.
  • Implementation of a multi-channel second dimension (2D) with a flow-through vapor detector for 1D peak reconstruction.

Main Results:

  • The portable GC x GC device achieved a 2D peak capacity of 430-530.
  • Peak capacity production reached 40-80/min.
  • Successful separation of 50 analytes, including alkanes, alkenes, alcohols, aldehydes, ketones, cycloalkanes, and aromatic hydrocarbons, within 14 minutes.
  • Significantly improved 1D resolution through joint 1D and 2D detector information.

Conclusions:

  • The developed portable GC x GC system offers enhanced separation power in a compact form factor.
  • The system's design and algorithms enable efficient and high-resolution analysis of complex mixtures.
  • This technology has the potential for field-deployable chemical analysis.