Related Experiment Video
Updated: Aug 27, 2026

Non-invasive Assessment of Microvascular and Endothelial Function
Published on: January 29, 2013
Raynaud's disease: reduced hand blood flows with normal blood viscosity
Abstract:
Hand blood flows and the blood and plasma viscosities were measured in patients with Raynaud's disease in an attempt to identify the mechanism of the episodic vascular insufficiency. Using venous occlusion plethysmography the following observations were made: (1) the hand blood flows were significantly less than in normals at 32 degrees, 27 degrees and 20 degrees C; (2) the percentage decrease in flow with cooling was greater in normals and (3) cooling of one hand from 32 degrees to 27 degrees C caused an abnormal decrease in flow through the contralateral hand. Using a rotational viscometer the blood and plasma viscosities were found to be normal at both high and low shear rates. The percentage increase in the blood viscosity with cooling from 35 degrees to 25 degrees was also normal. These studies demonstrate an increased constrictive response of the cutaneous vasculature of the hand to both local and reflex stimulation, and exclude a rheological abnormality, under conditions similar to those of the present study.
More Related Videos
08:42Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research
Published on: October 22, 2014
06:04Pulse-Wave Velocity, Flow-Mediated Dilation, and Carotid Intima-Media Thickness to Assess Cardiovascular Risk in Population with Metabolic Syndrome
Published on: September 27, 2024
Related Concept Videos
Blood Flow
Vascular Resistance
The primary determinants of vascular resistance are vessel diameter, blood viscosity, and vessel length. Among these, vessel diameter plays the most significant role due to the fourth power relationship described by...
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation.
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation