Related Experiment Video
Updated: Mar 14, 2026

Technique and Patient Selection Criteria of Right Anterior Mini-Thoracotomy for Minimal Access Aortic Valve Replacement
Published on: March 26, 2018
Should We Perform Carotid Doppler Screening Before Surgical or Transcatheter Aortic Valve Replacement?
Jose F Condado1, Hanna A Jensen2, Aneel Maini1
1Division of Cardiology, Structural Heart and Valve Center, Atlanta, Georgia.
Background:
Screening for internal carotid artery stenosis (ICAS) with Doppler ultrasound is commonly used before cardiovascular surgery. Nevertheless, the relationship between ICAS and procedure-related stroke in isolated aortic valve replacement is unclear.
Methods:
We retrospectively reviewed patients with artery stenosis who underwent ICAS screening before surgical (SAVR) or transcatheter aortic valve replacement (TAVR) between January 2007 and August 2014. Logistic regression models were used to determine the relation between post-procedure stroke and total (sum of left and right ICAS) and maximal unilateral ICAS. Age, sex, history of atrial fibrillation, cerebrovascular disease and diabetes, left ventricular ejection fraction, and procedure type were considered as covariates. Two-subgroup analyses were performed in patients who underwent TAVR and SAVR, adjusting for procedure specific details.
Results:
A total of 996 patients underwent ICAS screening before TAVR (n = 467) or SAVR (n = 529). The prevalence of at least ≥70% ICAS was 5.2% (n = 52) and incidence of 30-day stroke was 3.4% (n = 34). Eight patients who underwent carotid intervention before valve replacement and 6 patients with poor Doppler images were excluded from the final analysis. We found no statistically significant association between stroke and either the total or maximal unilateral ICAS for all patients (p = 0.13 and p = 0.39, respectively) or those undergoing TAVR (p = 0.27 and p = 0.63, respectively) or SAVR (p = 0.21 and p = 0.36, respectively).
Conclusions:
We found no statistically significant association between ICAS severity procedure-related stroke after aortic valve replacement. This suggests that universal carotid Doppler screening before isolated TAVR or SAVR is unnecessary.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
06:04Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
Related Concept Videos
Aneurysm IV: Nursing Management
Aortic Regurgitation III: Medical Management
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Imaging Studies for Cardiovascular System V: CT