Related Experiment Video
Updated: Mar 13, 2026

Novel Mini-open Transforaminal Lumbar Interbody Fusion
Published on: June 6, 2025
Dural Traction a Possible Cause of Hemodynamic Changes During Single-Level Transforaminal Lumbar Interbody Fusion
Jonathan M Weimer1, Martin Marinov2, Rafi Avitsian3
1Department of Internal Medicine, Cleveland Clinic, Cleveland, Ohio, USA.
Background:
Lumbar spinal surgery may be associated with electrophysiologic and hemodynamic abnormalities during the procedure.
Case Description:
A 58-year-old man with grade II L4-5 spondylolisthesis and degenerative changes underwent single-level transforaminal lumbar interbody fusion. During decompression of the L4 foramina, distraction of the disc space, and placement of the interbody cage and pedicle screws, episodes of extreme bradycardia with up to 5 seconds of asystole were detected on electrocardiogram and invasive hemodynamic monitoring. The events correlated with and possibly could have been a result of traction on the dura mater.
Conclusions:
Anesthesia providers should be aware of electrophysiologic and hemodynamic abnormalities during lumbar spinal surgery and the need to respond appropriately with sympathomimetic or vagolytic interventions.