Correlation between PaO2/FiO2 and airway and vascular parameters in the assessment of cellular ex vivo lung perfusion
Toshihiro Okamoto1, David Wheeler2, Qiang Liu3
1Department of Pathobiology, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA; Department of Thoracic and Cardiovascular Surgery, Cleveland Clinic, Cleveland, Ohio, USA; Transplant Center, Cleveland Clinic, Cleveland, Ohio, USA.
Background:
Ex vivo lung perfusion (EVLP) may be an essential process for the pre-transplant evaluation of the donor lungs. Currently, the partial pressure of oxygen/fraction of inspired oxygen (PaO2/FiO2, or PF) ratio is the standard in the assessment of lung function in cellular EVLP, whereas other parameters, including airway and vascular parameters, have only been partially utilized. The primary purpose of this study is to assess the potential utility of other parameters as a surrogate of lung function in EVLP.
Methods:
Yorkshire swine lungs (n = 12) and rejected human donor lungs (n = 12) were perfused in cellular-based EVLP for 2 hours. PF ratio, airway parameters (peak airway pressure, plateau pressure, dynamic compliance and static compliance) and vascular parameters (pulmonary vascular resistance and pulmonary artery pressure) were measured. The correlations between PF ratio and one of these parameters were analyzed.
Results:
Correlations were identified in the following combinations: PF ratio and airway parameters (p < 0.05, each); PF ratio and vascular parameters (p < 0.05, each); static compliance and pulmonary vascular resistance in swine lungs (p = 0.0001); and PF ratio and airway parameters in rejected human lungs (p < 0.05, each). There were significant differences in all parameters between suitable cases and non-suitable cases in swine lungs (p < 0.02, each).
Conclusions:
Our results show that airway parameters are complementary quantitative indicators of lung function in cellular EVLP, based on the correlations with PF ratio in both swine lungs and human lungs.
More Related Videos
09:47Author Spotlight: Utilizing Next-Generation Polymerized Human Hemoglobin for Improved Donor Lung Evaluation and Preservation in Rats
Published on: June 14, 2024
09:31Normothermic Negative Pressure Ventilation Ex Situ Lung Perfusion: Evaluation of Lung Function and Metabolism
Published on: February 14, 2022
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...