Biomechanical analysis of the effect of congruence, depth and radius on the stability ratio of a simplistic 'ball-and-socket' joint model
Related Experiment Video
Updated: Mar 13, 2026

Measuring 3D In-vivo Shoulder Kinematics using Biplanar Videoradiography
Published on: March 12, 2021
L Ernstbrunner1, J-D Werthel2, T Hatta2
1Department of Orthopaedics and Traumatology, Paracelsus Medical University, Salzburg, Austria and Department of Orthopaedics, Balgrist University Hospital, University of Zurich, Switzerland, Zurich, Switzerland lukas.ernstbrunner@stud.pmu.ac.at.
Objectives:
The bony shoulder stability ratio (BSSR) allows for quantification of the bony stabilisers in vivo. We aimed to biomechanically validate the BSSR, determine whether joint incongruence affects the stability ratio (SR) of a shoulder model, and determine the correct parameters (glenoid concavity versus humeral head radius) for calculation of the BSSR in vivo.
Methods:
Four polyethylene balls (radii: 19.1 mm to 38.1 mm) were used to mould four fitting sockets in four different depths (3.2 mm to 19.1mm). The SR was measured in biomechanical congruent and incongruent experimental series. The experimental SR of a congruent system was compared with the calculated SR based on the BSSR approach. Differences in SR between congruent and incongruent experimental conditions were quantified. Finally, the experimental SR was compared with either calculated SR based on the socket concavity or plastic ball radius.
Results:
The experimental SR is comparable with the calculated SR (mean difference 10%, sd 8%; relative values). The experimental incongruence study observed almost no differences (2%, sd 2%). The calculated SR on the basis of the socket concavity radius is superior in predicting the experimental SR (mean difference 10%, sd 9%) compared with the calculated SR based on the plastic ball radius (mean difference 42%, sd 55%).
Conclusion:
The present biomechanical investigation confirmed the validity of the BSSR. Incongruence has no significant effect on the SR of a shoulder model. In the event of an incongruent system, the calculation of the BSSR on the basis of the glenoid concavity radius is recommended.Cite this article: L. Ernstbrunner, J-D. Werthel, T. Hatta, A. R. Thoreson, H. Resch, K-N. An, P. Moroder. Biomechanical analysis of the effect of congruence, depth and radius on the stability ratio of a simplistic 'ball-and-socket' joint model. Bone Joint Res 2016;5:453-460. DOI: 10.1302/2046-3758.510.BJR-2016-0078.R1.
Related Concept Videos
Space Trusses: Problem Solving
Consider a tripod consisting of a tetrahedral space truss with a ball-and-socket joint at C. Suppose the height and lengths of the horizontal and vertical...
Stability of Equilibrium Configuration: Problem Solving
Problem-solving in the context of the stability of equilibrium configuration...
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...
Radius of Gyration of an Area
Stability of structures
Equations of Equilibrium in Three Dimensions
According to the vector equations of equilibrium, the vector sum of all the external forces acting on a body must...

