Related Experiment Video
Updated: Mar 13, 2026

Coherent anti-Stokes Raman Scattering CARS Microscopy Visualizes Pharmaceutical Tablets During Dissolution
Published on: July 4, 2014
In-Process Control Assay of Pharmaceutical Microtablets Using Hyperspectral Imaging Coupled with Multivariate
Lalit Mohan Kandpal1, Jagdish Tewari2, Nishanth Gopinathan3
1Department of Biosystems Machinery Engineering, College of Agricultural and Life Science, Chungnam National University , 99 Daehak-ro, Yuseong-gu, Daejeon 34134, South Korea.
Abstract:
Monitoring the amount of active pharmaceutical ingredient (API) in finished dosage form is important to ensure the content uniformity of the product. In this report, we summarize the development and validation of a hyperspectral imaging (HSI) technique for rapid in-line prediction of the active pharmaceutical ingredient (API) in microtablets with concentrations varying from 60 to 130% API (w/w). The tablet spectra of different API concentrations were collected in-line using an HSI system within the visible/near-infrared (vis/NIR; 400-1000 nm) and short-wave infrared (SWIR; 1100-2500 nm) regions. The ability of the HSI technique to predict the API concentration in the tablet samples was validated against a reference high-performance liquid chromatography (HPLC) method. The prediction efficiency of two different types of multivariate data modeling methods, that is, partial least-squares regression (PLSR) and principle component regression (PCR), were compared. The prediction ability of the regression models was cross-validated against results generated with the reference HPLC method. The results obtained from the PLSR models showed reliable performance for predicting the API concentration in SWIR region. The highest coefficient of determination (R2p) was 0.96, associated with the lowest predicted error and bias of 4.45 and -0.35%, respectively. Furthermore, the concentration-mapped images of PLSR and PCR models were used to visually characterize the API concentration present on the tablet surface. Based on these results, we suggest that HSI measurement combined with multivariate data analysis and chemical imaging could be implemented in the production environment for rapid in-line determination of pharmaceutical product quality.
More Related Videos
07:05Correlative Optical Spectroscopy and Mass Spectrometry Imaging Methodology to Visualise Drug Distribution in a Soft Tissue Section
Published on: June 20, 2025
08:49Author Spotlight: Unveiling the Potential of VSFG Microscopy in Studying Mesoscopically Heterogeneous Self-Assembled Structures