Kidney function and appropriateness of device therapies in adults with implantable cardioverter defibrillators
Nisha Bansal1, Adam Szpiro2, Frederick Masoudi3
1Division of Nephrology, Kidney Research Institute, University of Washington, Seattle, Washington, USA.
Insights
Chronic kidney disease (CKD) did not increase the risk of device therapies in patients receiving primary prevention implantable cardioverter defibrillators (ICDs). These findings suggest CKD should not prevent eligible patients from receiving ICDs.
Area of Science:
- Cardiology
- Nephrology
- Medical Devices
Background:
- Patients with chronic kidney disease (CKD) face a higher risk of sudden cardiac death.
- Implantable cardioverter defibrillators (ICDs) are crucial for preventing sudden cardiac death.
- Concerns exist regarding increased complication risks, including device therapies, in CKD patients receiving ICDs.
Purpose of the Study:
- To evaluate the association between CKD and the risk of device-delivered shocks or antitachycardia pacing (ATP) therapies in primary prevention ICD recipients.
- To determine if CKD influences the timing, burden, or appropriateness of ICD therapies.
Main Methods:
- A cohort study of 2161 participants receiving primary prevention ICDs was analyzed.
- CKD was defined as an estimated glomerular filtration rate (eGFR) <60 mL/min/1.73 m².
- Outcomes included all delivered shocks/ATPs, their appropriateness, and timing over 3 years, with adjustments for covariates.
Main Results:
- Among 2161 participants, 49.3% had CKD.
- CKD was not associated with the time to first shock/ATP therapy (aHR 0.87; 95% CI 0.73-1.05).
- No significant association was found between CKD and the overall burden or appropriateness of device therapies.
Conclusions:
- Mild-to-moderate CKD is not associated with increased risk of timing, burden, or appropriateness of ICD therapies.
- Concerns about inappropriate ICD therapies should not deter ICD implantation in eligible CKD patients.
- Further research may explore specific CKD subpopulations and advanced device therapies.
Objective:
Patients with chronic kidney disease (CKD) have higher risk of sudden cardiac death; however, they may not receive implantable cardioverter defibrillators (ICDs), in part due to higher risk of complications. We evaluated whether CKD is associated with greater risk of device-delivered shocks/antitachycardia pacing (ATP) therapies among patients receiving a primary prevention ICD.
Methods:
We studied participants in the observational Cardiovascular Research Network Longitudinal Study of Implantable Cardioverter Defibrillators. CKD was defined as estimated glomerular filtration rate (eGFR) <60 mL/min/1.73 m2. Outcomes included all delivered shocks/ATPs therapies and type of shock/ATP therapies (inappropriate or appropriate, determined by physician adjudication) within the 3 years. We evaluated the associations between CKD and time to first device therapy, burden of device therapy, and inappropriate versus appropriate device therapy, adjusting for demographics, comorbidity, laboratory values and medication use.
Results:
Among 2161 participants, 1066 (49.3%) had CKD (eGFR 44±11 mL/min/1.73 m2) at ICD implantation. During mean of 2.26±0.89 years, 9.8% and 18.5% of participants had at least one inappropriate and appropriate shock/ATP therapies, respectively. CKD was not associated with time to first shock/ATP therapies (adjusted HR 0.87, 95% CI 0.73 to 1.05), overall burden of shock/ATP therapies (adjusted relative rate 0.93, 95% CI 0.74 to 1.17) or inappropriate versus appropriate shock/ATP therapies (adjusted relative risk 0.88, 95% CI 0.68 to 1.14) compared with not having CKD.
Conclusions:
In adults receiving a primary prevention ICD, mild-to-moderate CKD was not associated with the timing, burden or appropriateness of subsequent device therapy. Potential concern for inappropriate ICD-delivered therapies should not preclude ICDs among eligible patients with CKD.