Related Experiment Video
Updated: Mar 13, 2026

Author Spotlight: Advancements in Impedance Monitoring for Cochlear Implant Surgery
Published on: August 4, 2023
Vestibular Function After Cochlear Implantation: A Comparison of Three Types of Electrodes
Jonas Frodlund1, Henrik Harder, Elina Mäki-Torkko
1*Department of Otorhinolaryngology in Linköping, Anaesthetics, Operations and Specialty Surgery Center, Region Östergötland†Division of Neuro and Inflammation Science, Department of Clinical and Experimental Medicine, Linköping University‡Linneaus Centre HEAD, Linköping University, Sweden.
Objective:
To investigate the vestibular function after cochlear implantation with different types of electrode arrays.
Study Design:
Retrospective cohort study.
Setting:
Academic tertiary referral center.
Materials And Methods:
Forty three adults underwent first cochlear implantation. Three consecutive series of patients: Group 1 (n = 13) implanted with a precurved electrode, Group 2 (n = 15) implanted with a straight electrode, Group 3 (n = 15) implanted with a flexible electrode. Patient's vestibular functions were assessed with pre- and postoperative caloric testing using videonystagmography (VNG). The postoperative reduction of the maximum slow phase velocity (MSPV) in the implanted ear was evaluated. Medical charts were reviewed to evaluate the occurrence of late onset of postoperative vestibular symptoms.
Results:
Mean reduction of MSPV was 7.6/s (standard deviation [SD] 8.0) in Group 1, 23.1/s (SD 16.6) in Group 2, and 0.1/s (SD 18.5) in Group 3. Significant difference was found between Group 1 and 2 (p < 0.030) and between Group 2 and 3 (p < 0.001). Group 2 showed a higher prevalence of late onset of clinical vertigo (28.6%) than Group 1 (7.7%) and 3 (6.7%).
Conclusion:
In this prospective study, significantly larger reductions of caloric responses were found in subjects implanted with a straight electrode compared with subjects implanted with a precurved or flexible electrode. These findings seem to correlate to a higher prevalence of postoperative vertigo.
Related Concept Videos
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
The Vestibular System

