Targeted and non-targeted drug screening in whole blood by UHPLC-TOF-MS with data-independent acquisition
Christian Brinch Mollerup1, Petur Weihe Dalsgaard1, Marie Mardal1
1Section of Forensic Chemistry, Department of Forensic Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Denmark.
Abstract:
High-resolution mass spectrometry (HRMS) is widely used for the drug screening of biological samples in clinical and forensic laboratories. With the continuous addition of new psychoactive substances (NPS), keeping such methods updated is challenging. HRMS allows for combined targeted and non-targeted screening. First, peaks are identified by software algorithms, and identifications are based on reference standard data. Attempts are made to identify the remaining unknown peaks with in silico and literature data. However, several thousand peaks remain where most are unidentifiable or uninteresting in drug screening. The aims of the study were to apply a combined targeted and non-targeted screening approach to authentic driving-under-the-influence-of-drugs (DUID) samples (n = 44) and further validate the approach using whole-blood samples spiked with 11 low-dose synthetic benzodiazepine analogues (SBAs). Analytical data were acquired using ultra-high-performance liquid chromatography coupled with a time-of-flight mass spectrometer (UHPLC-TOF-MS) with data-independent acquisition (DIA). We present a combined targeted and non-targeted screening, where peak deconvolution and filtering reduced the number of peaks to inspect by three orders of magnitude, down to four peaks per DUID sample. The screening allowed for tentative identification of metabolites and drugs not included in the initial screening; 3 drugs and 14 metabolites were tentatively identified in the authentic DUID samples. Running targeted-screening true-positive identifications through the filters retained 73% of identifications. In the non-targeted screening, nine of the spiked SBAs were identified in the concentration range of 0.005-0.1 mg/kg, of which three were tentatively identified at concentrations below those reported in the literature. Copyright © 2016 John Wiley & Sons, Ltd.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
07:34Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
Published on: March 14, 2013
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...