Preparation and In Vitro Characterization of Dendrimer-based Contrast Agents for Magnetic Resonance Imaging
Published on: December 4, 2016
Catechin tuned magnetism of Gd-doped orthovanadate through morphology as T1-T2 MRI contrast agents
Tamilmani Vairapperumal1, Ariya Saraswathy2, Jayasree S Ramapurath3
1Chemical laboratory, CSIR-Central Leather Research Institute, Adyar, Chennai, 600 020, India.
Abstract:
Tetragonal (t)-LaVO4 has turned out to be a potential host for luminescent materials. Synthesis of t-LaVO4 till date has been based on chelating effect of EDTA making it not ideal for bioimaging applications. An alternative was proposed by us through the use of catechin. In recent times there is interest for new MRI contrast agents that can through appropriate doping function both as MRI contrast and optical/upconversion materials. It is generally believed that under appropriate doping, t-LaVO4 would be a better upconversion material than monoclinic (m)-LaVO4. Based on these postulations, this work explores the use of gadolinium doped t-LaVO4 as an MRI contrast agent. From literature, gadolinium oxide is a good T1 contrast agent. Through this work, using catechin as a template for the synthesis of Gd doped t-LaVO4, we demonstrate the possible use as a T1 contrast agent. Interestingly, as the catechin concentration changes, morphology changes from nanorods to square nanoplates and spheres. In this process, a switch from T1 to T2 contrast agent was also observed. Under optimal concentration of catechin, with a rod shaped Gd doped t-LaVO4 an r2/r1 value of 21.30 was observed. Similarly, with a spherical shape had an r2/r1 value of 1.48 was observed.
Related Concept Videos
Magnetic Resonance Imaging
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...