Reliable Acquisition of Electroencephalography Data during Simultaneous Electroencephalography and Functional MRI
Published on: March 19, 2021
"Eyes Open - Eyes Closed" EEG/fMRI data set including dedicated "Carbon Wire Loop" motion detection channels
Johan van der Meer1, André Pampel2, Eus van Someren3
1Clinical Affective Neuroimaging Laboratory, Otto-von-Guericke University, Magdeburg, Germany; Department of Behavioral Neurology, Leibniz Institute for Neurobiology, Magdeburg, Germany; Department of Neurology, Otto-von-Guericke University, Magdeburg, Germany; Department of Medical Psychology, Center for Neurogenomics and Cognitive Research (CNCR), Neuroscience Campus Amsterdam, VU University and Medical Center, Amsterdam, The Netherlands.
Abstract:
This data set contains electroencephalography (EEG) data as well as simultaneous EEG with functional magnetic resonance imaging (EEG/fMRI) data. During EEG/fMRI, the EEG cap was outfitted with a hardware-based add-on consisting of carbon-wire loops (CWL). These yielded six extra׳CWL׳ signals related to Faraday induction of these loops in the main magnetic field "Measurement and reduction of motion and ballistocardiogram artefacts from simultaneous EEG and fMRI recordings" (Masterton et al., 2007) [1]. In this data set, the CWL data make it possible to do a direct regression approach to deal with the BCG and specifically He artifact. The CWL-EEG/fMRI data in this paper has been recorded on two MRI scanners with different Helium pump systems (4 subjects on a 3 T TIM Trio and 4 subjects on a 3T VERIO). Separate EEG/fMRI data sets have been recorded for the helium pump ON as well as the helium pump OFF conditions. The EEG-only data (same subjects) has been recorded for a motion artifact-free reference EEG signal outside of the scanner. This paper also links to an EEGlab "EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis" (Delorme and Makeig, 2004) [2] plugin to perform a CWL regression approach to deal with the He pump artifact, as published in the main paper "Carbon-wire loop based artifact correction outperforms post-processing EEG/fMRI corrections-A validation of a real-time simultaneous EEG/fMRI correction method" (van der Meer et al., 2016) [3].
More Related Videos
11:28Concurrent EEG and Functional MRI Recording and Integration Analysis for Dynamic Cortical Activity Imaging
Published on: June 30, 2018
10:23Equipment Setup and Artifact Removal for Simultaneous Electroencephalogram and Functional Magnetic Resonance Imaging for Clinical Review in Epilepsy
Published on: June 23, 2023