Background:
In the selection of an appropriate IUD little consideration is placed on device size or adequacy of fit. Properly fitting IUDs will likely lead to less adverse effects or patient discomfort resulting in enhanced continuation of use.
Methods:
A multicenter study conducted at 7 centers in 410 nulliparous women, to measure the width of the uterine cavity using 2D and 3D ultrasound.
Results:
Measurements of maximal fundal cavity width was performed by either 2D or 3D ultrasound by experienced sonographists. The mean width of the uterine cavity in the fundus was 22.2mm (range 6.0-41.1mm). There was no statistical difference in the values whether determined by 2D (n=258) or 3D (n=152) measurements having a median value of 22.5mm and 21.6mm, respectively, 79% of women had a uterine cavity width between 15mm and 28mm, 32%<20mm and 6.8%<15mm, respectively.
Discussion:
Uterine cavities in nulliparous women are narrow and rarely wide enough to fit conventional IUDs. Gross discrepancy between the IUD and the uterine cavity leads to side effect (e.g., expulsion, embedment, bleeding, pain) and early discontinuation. Historically, devices too large for the uterine cavity have been routinely inserted which may account for their 5-year continuation rates being only 40 to 50%. Our study suggests that preprocedural 2D or 3D sonography to measure the width of the uterine cavity may result in the selection of a suitable IUD to maximize continuation of use. Measurement of the cavity width is not necessary with a frameless IUD.
More Related Videos
07:44Non-Invasive Ultrasound Assessment of Endometrial Cancer Progression in Pax8-Directed Deletion of the Tumor Suppressors Arid1a and Pten in Mice
Published on: February 17, 2023
06:43High Frequency Ultrasound for the Analysis of Fetal and Placental Development In Vivo
Published on: November 8, 2018
Related Concept Videos
Imaging Studies II: Ultrasonography
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Uterus and Cervix
The uterus is securely anchored within the pelvic cavity by paired broad ligaments on either side. It is further stabilized by three pairs...