Raman spectroscopy is a rapid, non-destructive and non-invasive method that is a promising tool for real-time analytical control of drug concentrations. This study evaluated a handheld Raman device to discriminate and quantify two isomeric drugs used to treat cancer. Doxorubicin (DOXO) and epirubicin (EPIR) samples were analyzed at therapeutic concentrations from 0.1 to 2mg/mL (n=90) and 0.08-2mg/mL (n=90) by non-invasive measurements using a portable Raman spectrometer. The discrimination of these two molecules was demonstrated for all concentrations (n=180) by qualitative analysis using partial least square discriminant analysis (PLS-DA) with 100% classification accuracy, sensitivity and specificity and 0% error rate. For each molecule, quantitative analyses were performed using PLS regression. The validity of the model was evaluated using root mean square error of cross validation (RMSECV) and prediction (RMSEP) that furnished 0.05 and 0.02mg/mL for DOXO and 0.17 and 0.16mg/mL for EPIR after pretreatment optimization. Based on the accuracy profile, the linearity range was from 1.256 to 2.000mg/mL for DOXO (R2=0.9988) and from 0.553 to 2.000mg/Ml for EPIR (R2=0.9240) and repeatability (CV% max of 1.8% for DOXO and 3.2% for EPIR) and intermediate precision (CV% max of 2.8% for DOXO and 4.5% for EPIR) were both acceptable. Despite the narrow validated concentration range for quantitative analysis, this study shows the potential of a handheld Raman spectrometer coupled to chemometric approaches for real-time quantification of cytotoxic drugs, as well for discriminating between two drugs with similar UV absorption profiles. Finally, the use of a handheld spectrometer with the possibility of a direct measurement of substances in containers is a potentially valuable tool for combining patient safety with security of healthcare workers.
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Spectrophotometry: Introduction