Related Experiment Video
Updated: Mar 13, 2026

Generation of Electronic Cigarette Aerosol by a Third-Generation Machine-Vaping Device: Application to Toxicological Studies
Published on: August 25, 2018
A randomised, parallel group study to evaluate the safety profile of an electronic vapour product over 12 weeks
Ana S Cravo1, Jim Bush2, Girish Sharma3
1Fontem Ventures, Barbara Strozzilaan 101, 1083 HN, Amsterdam, Netherlands.
Abstract:
A randomised, parallel group clinical study was performed to evaluate the safety profile of an e-vapour product (EVP; 2.0% nicotine) in smokers of conventional cigarettes (CCs) switching to use the EVP for 12 weeks. During the study, no clinically significant product-related findings were observed in terms of vital signs, electrocardiogram, lung function tests and standard clinical laboratory parameters. Adverse events (AEs) reported by EVP subjects were more frequent during the first week after switching to the EVP. The frequency of AEs reduced thereafter and out of a total of 1515 reported AEs, 495 were judged as being related to nicotine withdrawal symptoms. The most frequently stated AEs were headache, sore throat, desire to smoke and cough reported by 47.4, 27.8, 27.5 and 17.0% of subjects, respectively. Only 6% of AEs were judged as probably or definitely related to the EVP. Additional observations in EVP subjects included a decrease in the level of urine nicotine equivalents by up to 33.8%, and decreases in the level of three biomarkers of exposure to toxicants known to be present in CC smoke (benzene, acrolein and 4-[methylnitrosamino]-1-[3-pyridyl]-1-butanone). The decrease in nicotine equivalents coincided with an increase in nicotine withdrawal symptoms, measured by a questionnaire, which subsided after two weeks. The data presented here shows the potential EVPs may offer smokers looking for an alternative to CCs.
More Related Videos
10:44Comparing the Effects of Electronic Cigarette Vapor and Cigarette Smoke in a Novel In Vivo Exposure System
Published on: May 24, 2017
09:30A Microcontroller Operated Device for the Generation of Liquid Extracts from Conventional Cigarette Smoke and Electronic Cigarette Aerosol
Published on: January 18, 2018
Related Concept Videos
Bioavailability Study Design: Healthy Subjects Versus Patients
Bioavailability Study Design: Single Versus Multiple Dose Studies
Stimulants
Cocaine can be administered via snorting, injection, or smoking. It primarily functions by blocking the reuptake of dopamine, resulting in a euphoric high characterized by an intense sensation of happiness and...
Clinical Trials
There are four phases in a clinical trial. A phase one...
Bioequivalence studies: Biowaivers