Related Experiment Video
Updated: Mar 13, 2026

Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
Does ventilator-associated event surveillance detect ventilator-associated pneumonia in intensive care units? A
Yunzhou Fan1, Fang Gao1, Yanyan Wu1
1Department of Nosocomial Infection Management, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 JieFang Avenue, Wuhan, 430022, China.
Background:
Ventilator-associated event (VAE) is a new surveillance paradigm for monitoring complications in mechanically ventilated patients in intensive care units (ICUs). The National Healthcare Safety Network replaced traditional ventilator-associated pneumonia (VAP) surveillance with VAE surveillance in 2013. The objective of this study was to assess the consistency between VAE surveillance and traditional VAP surveillance.
Methods:
We systematically searched electronic reference databases for articles describing VAE and VAP in ICUs. Pooled VAE prevalence, pooled estimates (sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV)) of VAE for the detection of VAP, and pooled estimates (weighted mean difference (WMD) and odds ratio ([OR)) of risk factors for VAE compared to VAP were calculated.
Results:
From 2191 screened titles, 18 articles met our inclusion criteria, representing 61,489 patients receiving mechanical ventilation at ICUs in eight countries. The pooled prevalence rates of ventilator-associated conditions (VAC), infection-related VAC (IVAC), possible VAP, probable VAP, and traditional VAP were 13.8 %, 6.4 %, 1.1 %, 0.9 %, and 11.9 %, respectively. Pooled sensitivity and PPV of each VAE type for VAP detection did not exceed 50 %, while pooled specificity and NPV exceeded 80 %. Compared with VAP, pooled ORs of in-hospital death were 1.49 for VAC and 1.76 for IVAC; pooled WMDs of hospital length of stay were -4.27 days for VAC and -5.86 days for IVAC; and pooled WMDs of ventilation duration were -2.79 days for VAC and -2.89 days for IVAC.
Conclusions:
VAE surveillance missed many cases of VAP, and the population characteristics identified by the two surveillance paradigms differed. VAE surveillance does not accurately detect cases of traditional VAP in ICUs.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Acute Respiratory Failure-III
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...

