Relation Between Clinical Best Practices and 6-Month Outcomes After Transcatheter Aortic Valve Implantation With
Jan-Malte Sinning1, Anna Sonia Petronio2, Nicolas Van Mieghem3
1Department of Medicine II, Heart Center Bonn, University Hospital Bonn, Bonn, Germany.
Abstract:
Best practices for transcatheter aortic valve implantation with CoreValve include patient screening and valve size selection using multislice computed tomography, adherence to manufacturer recommendations for oversizing, control of implant depth to 6 mm or less, and management of conduction disturbances according to international guidelines. The ADVANCE II study implemented these strategies and demonstrated their relation to clinical outcomes. From October 2011 to April 2013, 200 patients with severe aortic stenosis were enrolled, and 194 were implanted. All imaging and electrocardiographic data were analyzed by an independent core laboratory, and adverse events were adjudicated to valve academic research consortium-2 definitions. The mean age was 80.2 ± 6.7 years and the mean Society of Thoracic Surgeons Predicted Risk of Mortality was 7.2 ± 6.8% for the enrolled patients. At 6 months, all-cause mortality was 9.2%, stroke was 2.6%, and permanent pacemaker implantation was 19.2% for class I and II indications. In patients with implant depth ≤6 mm, both mortality and permanent pacemaker implantation were lower than in patients with depth >6 mm (2.5% vs 14.5%, p <0.01 and 18.1% vs 31.7%, p = 0.03, respectively). The rate of moderate and severe paravalvular leak was 9.8% at 7 days after transcatheter aortic valve implantation, decreasing to 4.3% at 6 months (p = 0.02). Valves were significantly more oversized in patients with mild or less paravalvular leak at day 7 compared with those with moderate or severe (15.8 ± 8.0% vs 11.8 ± 4.9%, p = 0.01). In conclusion, findings from the ADVANCE II study reinforce that adherence to best clinical practices improves patient outcomes.
Related Concept Videos
Aortic Regurgitation III: Medical Management
Mitral Valve Prolapse II: Assessment and Management
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Stenosis III: Medical Management
Mitral Stenosis I: Introduction
Mitral Valve Prolapse I: Introduction