Related Experiment Video
Updated: Jan 22, 2026

Sample Preparation in Quartz Crystal Microbalance Measurements of Protein Adsorption and Polymer Mechanics
Published on: January 22, 2020
Real-time label-free detection and kinetic analysis of Etanercept-Protein A interactions using quartz crystal
Evan A Dubiel1, Bruno Martin2, Sylvain Vigier1
1Laboratoire de bio-ingénierie et de biophysique de l'Université de Sherbrooke, Department of Chemical and Biotechnological Engineering, Université de Sherbrooke, 2500, boulevard de l'Université, Sherbrooke, Québec J1K 2R1, Canada; Research Centre on Aging, Institut universitaire de gériatrie de Sherbrooke, 1036, rue Belvédère Sud, Sherbrooke, Québec J1H 4C4, Canada.
Abstract:
A quartz crystal microbalance (QCM) was constructed to assess if such a biosensor has value as a complementary real-time label-free analysis platform for the biopharmaceutical industry. This was achieved through modifying QCM crystals with a low-fouling carboxymethyl-dextran layer bearing Protein A, and then injecting solutions containing Etanercept (i.e., Enbrel®) into the QCM chambers. The kinetics of Enbrel® - Protein A interactions was modeled using the Langmuir binding model and Enbrel® concentrations between 0.75-300ngmL-1. The resulting equilibrium dissociation and association constants (KD and KA) were 5.06×10-8M and 1.98×107M-1, respectively. The association and dissociation rate constants (kon and koff) decreased substantially as Enbrel® concentration, [C], increased, despite that the net binding rate, (kon[C]+koff), increased. The decrease in kon and koff was hypothesized to be a consequence of mass transport limitations. To verify this, QCM dissipation measurements were analyzed to provide insight on solution viscosity. As Enbrel® concentration increased, the net change in dissipation, ΔD, became larger. An augmentation of ΔD is associated with a higher solution viscosity, which would result in an increase in mass transport limitations. Therefore, the decrease in kon and koff for increasing Enbrel® concentration can be attributed to mass transport limitations. In conclusion, QCM is a valuable complementary real-time label-free biosensor analysis platform for the biopharmaceutical industry. Unlike the surface plasmon resonance (SPR) platform, QCM allows measuring dissipation, which can provide insight on how mass transport limitations impact interaction kinetics.
Related Concept Videos
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
Kinetic Molecular Theory: Molecular Velocities, Temperature, and Kinetic Energy
Ionic Crystal Structures
Most monatomic ions behave as charged spheres, and their attraction for ions of opposite charge is the same in every direction. Consequently, stable structures for ionic compounds result (1) when ions of one charge are surrounded by as many ions as possible of the opposite...
Kinetic Energy
Protein-Drug Binding: Mechanism and Kinetics
Various forces drive these interactions, including hydrogen bonds, hydrophobic interactions, ionic bonds, electrostatic interactions, and van der Waals forces. These bonds enable drugs to bind to specific sites on proteins,...
Enzyme Kinetics
Scientists typically study enzyme kinetics with a fixed amount of enzyme in the controlled environment of a test tube. When more reactant, or substrate, is...

