Related Experiment Video
Updated: Mar 13, 2026

Crack Monitoring in Resonance Fatigue Testing of Welded Specimens Using Digital Image Correlation
Published on: September 29, 2019
Analysis of Crack Image Recognition Characteristics in Concrete Structures Depending on the Illumination and Image
Hyun-Woo Cho1, Hyuk-Jin Yoon2, Jae-Chan Yoon3
1Robotics and Virtual Engineering, University of Science and Technology, Uiwang-si 16105, Korea. hwcho@krri.re.kr.
Abstract:
The effects of illumination and shooting distance on crack image recognition were investigated by examining cracks in images taken with a camera. In order to examine the effects, images of cracks in a concrete structure taken while varying the illumination and shooting distance in an outdoor environment were analyzed. The images were acquired at a daytime illumination of 52,000 lx and a night illumination of 13 lx. The crack specimen images produced for the experiment were taken by increasing the shooting distance from 5 m to 100 m in each illumination. On the basis of the analysis on the modulation transfer function (MTF) and contrast sensitivity of the crack images, the effects of illumination and shooting distance on the sharpness of the crack images were investigated. The minimum crack widths that can be identified under each illumination were analyzed using MTF10 and Weber contrast 0.1, respectively. It was found that as the shooting distance increases, the effects of illumination on crack recognition become greater.
Related Concept Videos
Microcracking in Concrete
Determination of Crystal Structures