Abstract:
The aims of this study were to identify (1) patient-related factors (sex, age, craniofacial pattern and smoking habit), (2) miniscrews implants (MSI)-related factors (length and diameter) and (3) location-related factors [bone (maxilla or mandible) and area (buccal, lingual and alveolar ridge)] that may be associated with MSI loss of stability. A total of 1356 MSI were installed in 570 patients (423 females and 147 males) with mean age of 42.7 during a 10-year period and were clinically evaluated once a month until the end of the proposed movement. Length (5, 7, 9 and 11 mm) and diameter (1.3, 1.4 and 1.6 mm) of the MSI were selected according to insertion site. The evidence of clinical mobility during treatment or fracture during insertion was considered as failure. A total success rate of 89.1% was observed. There was no statistically significant difference in loss of stability when considering age, sex, craniofacial pattern or smoking habit. Considering diameter, there was no statistically significant difference (p = 0.645), but the shorter miniscrews (5 mm) showed higher failure rates (p < 0.001) than the longer ones. There were more loses (p < 0.001) in the mandible than in the maxilla, but the area (buccal, lingual or alveolar ridge) did not interfere in the results (p = 0,421). It can be concluded that MSIs are effective for skeletal anchorage in orthodontics. Patient-related factors, such as sex, age, smoking habit and craniofacial pattern, did not affect MSI success. However, the use of shorter MSIs (5 mm) was inversely proportional to failure probability, and loss of stability was greater in the mandible.
More Related Videos
09:07An Anesthesia, Surgery, and Harvest Method for the Evaluation of Transpedicular Screws Using an In Vivo Porcine Lumbar Spine Model
Published on: May 31, 2017
06:41A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
Related Concept Videos
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...