Dynamic Volume Computed Tomography Imaging of the Upper Airway in Obstructive Sleep Apnea
Robert J Fleck1, Stacey L Ishman2,3,4, Sally R Shott2,4
1Division of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, OH.
Study Objectives:
To describe a dynamic three-dimensional (3D) computed tomography (CT) technique for the upper airway and compare the required radiation dose to that used for common clinical studies of a similar anatomical area, such as for subjects undergoing routine clinical facial CT.
Methods:
Dynamic upper-airway CT was performed on eight subjects with persistent obstructive sleep apnea, four of whom were undergoing magnetic resonance imaging and an additional four subjects who had a contraindication to magnetic resonance imaging. This Health Insurance Portability and Accountability Act-compliant study was approved by our institutional review board, and informed consent was obtained. The control subjects (n = 41) for comparison of radiation dose were obtained from a retrospective review of the clinical picture-archiving computer system to identify 10 age-matched patients per age-based control group undergoing facial CT.
Results:
Dynamic 3D CT can be performed with an effective radiation dose of less than 0.38 mSv, a dose that is less than or comparable to that used for clinical facial CT. The resulting data- set is a uniquely complete, dynamic 3D volume of the upper airway through a full respiratory cycle that can be processed for clinical and modeling analyses.
Conclusions:
A dynamic 3D CT technique of the upper airway is described that can be performed with a clinically reasonable radiation dose and sets a benchmark for future use.
More Related Videos
Related Concept Videos
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Sleep Apnea
The condition is more prevalent among...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Respiratory Volumes and Capacities I
Respiratory Volumes and Capacities