Intravoxel incoherent motion modeling in the kidneys: Comparison of mono-, bi-, and triexponential fit
Sophie van Baalen1, Alexander Leemans2, Pieter Dik3
1MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, The Netherlands.
Purpose:
To evaluate if a three-component model correctly describes the diffusion signal in the kidney and whether it can provide complementary anatomical or physiological information about the underlying tissue.
Materials And Methods:
Ten healthy volunteers were examined at 3T, with T2 -weighted imaging, diffusion tensor imaging (DTI), and intravoxel incoherent motion (IVIM). Diffusion tensor parameters (mean diffusivity [MD] and fractional anisotropy [FA]) were obtained by iterative weighted linear least squares fitting of the DTI data and mono-, bi-, and triexponential fit parameters (D1 , D2 , D3 , ffast2 , ffast3 , and finterm ) using a nonlinear fit of the IVIM data. Average parameters were calculated for three regions of interest (ROIs) (cortex, medulla, and rest) and from fiber tractography. Goodness of fit was assessed with adjusted R2 ( Radj2) and the Shapiro-Wilk test was used to test residuals for normality. Maps of diffusion parameters were also visually compared.
Results:
Fitting the diffusion signal was feasible for all models. The three-component model was best able to describe fast signal decay at low b values (b < 50), which was most apparent in Radj2 of the ROI containing high diffusion signals (ROIrest ), which was 0.42 ± 0.14, 0.61 ± 0.11, 0.77 ± 0.09, and 0.81 ± 0.08 for DTI, one-, two-, and three-component models, respectively, and in visual comparison of the fitted and measured S0 . None of the models showed significant differences (P > 0.05) between the diffusion constant of the medulla and cortex, whereas the ffast component of the two and three-component models were significantly different (P < 0.001).
Conclusion:
Triexponential fitting is feasible for the diffusion signal in the kidney, and provides additional information.
Level Of Evidence:
2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:228-239.
Related Concept Videos
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Internal Anatomy of the Kidney
Anatomical Position and Dimensions
The kidneys are retroperitoneal organs positioned against the posterior abdominal wall on either side of the spine, roughly between the twelfth thoracic and third lumbar vertebrae. Each kidney is typically 10-12 cm long, 5-6 cm wide, and 3-4 cm thick, weighing about 150 grams.
Renal Cortex
The outermost region of the kidney is the...
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
External Anatomy of the Kidney
The kidneys are located in the retroperitoneal space on either side of the vertebral column, protected posteriorly by the 11th and 12th ribs. The right kidney sits slightly lower than the left owing to the presence of the liver...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System IV: CMRI