Related Experiment Video
Updated: Mar 13, 2026

Synthesis of 68Ga Core-doped Iron Oxide Nanoparticles for Dual Positron Emission Tomography /T1Magnetic Resonance Imaging
Published on: November 20, 2018
Nontoxic Formulations of Scintillation Nanocrystals for Use as X-ray Computed Tomography Contrast Agents
Jaewon Lee1, Seulgi Choi1, Ki Hyun Kim1
1School of Chemical Engineering, ‡Department of Veterinary Clinical Sciences, §Department of Comparative Pathobiology, and ∥Purdue University Center for Cancer Research, Purdue University , West Lafayette, Indiana 47907, United States.
Abstract:
X-ray computed tomography (CT) is currently one of the most powerful, noninvasive, clinical in vivo imaging techniques, which has resulted from advances in both X-ray device and contrast enhancement technologies. The present study demonstrates, for the first time, that metal tungstates (such as CaWO4) are promising contrast agents for X-ray, radiation, and CT imaging, because of the high X-ray mass attenuation of tungsten (W). We have developed a method of formulation, in which CaWO4 (CWO) nanoparticles (NPs) are encapsulated within a biocompatible poly(ethylene glycol-b-d,l-lactic acid) (PEG-PLA) block copolymer (BCP) capsule. We show that these PEG-PLA-encapsulated CWO NPs (170 ± 10 nm hydrodynamic diameter) produce a higher CT contrast (by a factor of about 2) than commercial iodine-based radiocontrast agents (e.g., Iohexol) at identical molar concentrations of W or I atoms. PEG-PLA-coated CWO NPs are chemically stable and completely nontoxic. It was confirmed that the maximum tolerated dose (MTD) of this material in mice is significantly higher (250 ± 50 mg per kg body weight following a single intravenous (IV) administration) than, for instance, commercially available dextran-coated iron oxide nanoparticles that are currently used clinically as MRI contrast agents (MTD in mice ≈ 168 mg/kg per dose IV). IV-injected PEG-PLA/CWO NPs caused no histopathologic damage in major excretory organs (heart, liver, lungs, spleen, and kidney). When an IV dose of 100 mg/kg was given to mice, the blood circulation half-life was measured to be about 4 h, and more than 90% of the NPs were cleared from the mice within 24 h via the renal and hepatobiliary systems. When intratumorally administered, PEG-PLA-coated CWO NPs showed complete retention in a tumor-bearing mouse model (measurements were made up to 1 week). These results suggest that PEG-PLA-coated CWO NPs are promising materials for use in CT contrast.
More Related Videos
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
08:41Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...