Inter-reader Variability in the Use of BI-RADS Descriptors for Suspicious Findings on Diagnostic Mammography: A
Amie Y Lee1, Dorota J Wisner1, Shadi Aminololama-Shakeri2
1Department of Radiology and Biomedical Imaging, University of California, 1600 Divisadero Street, Room C250, Box 1667, San Francisco, CA 94115.
Rationale And Objectives:
The study aimed to determine the inter-observer agreement among academic breast radiologists when using the Breast Imaging Reporting and Data System (BI-RADS) lesion descriptors for suspicious findings on diagnostic mammography.
Materials And Methods:
Ten experienced academic breast radiologists across five medical centers independently reviewed 250 de-identified diagnostic mammographic cases that were previously assessed as BI-RADS 4 or 5 with subsequent pathologic diagnosis by percutaneous or surgical biopsy. Each radiologist assessed the presence of the following suspicious mammographic findings: mass, asymmetry (one view), focal asymmetry (two views), architectural distortion, and calcifications. For any identified calcifications, the radiologist also described the morphology and distribution. Inter-observer agreement was determined with Fleiss kappa statistic. Agreement was also calculated by years of experience.
Results:
Of the 250 lesions, 156 (62%) were benign and 94 (38%) were malignant. Agreement among the 10 readers was strongest for recognizing the presence of calcifications (k = 0.82). There was substantial agreement among the readers for the identification of a mass (k = 0.67), whereas agreement was fair for the presence of a focal asymmetry (k = 0.21) or architectural distortion (k = 0.28). Agreement for asymmetries (one view) was slight (k = 0.09). Among the categories of calcification morphology and distribution, reader agreement was moderate (k = 0.51 and k = 0.60, respectively). Readers with more experience (10 or more years in clinical practice) did not demonstrate higher levels of agreement compared to those with less experience.
Conclusions:
Strength of agreement varies widely for different types of mammographic findings, even among dedicated academic breast radiologists. More subtle findings such as asymmetries and architectural distortion demonstrated the weakest agreement. Studies that seek to evaluate the predictive value of certain mammographic features for malignancy should take into consideration the inherent interpretive variability for these findings.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Magnetic Resonance Imaging