Continuous positive airway pressure usage in hospitalized patients with known obstructive sleep apnea: discrepancy
Parmeet Saini1, Emile Klada1, Vishal Patel1
1New York Methodist Hospital, Brooklyn, NY, 11215, USA.
Purpose:
The aim of this study was to determine the frequency and predictors of correctly initiated continuous positive airway pressure (CPAP) settings on the initial night of hospitalization in patients with known obstructive sleep apnea-hypopnea syndrome (OSAHS).
Methods:
Hospital records of all patients who underwent an outpatient therapeutic polysomnogram (PSG) at our institution between January 2005 and December 2010 were retrospectively reviewed. Data collected included initial CPAP settings on hospital admission, latency to hospitalization (from sleep study), hospital length of stay, demographic variables, and PSG variables.
Results:
One hundred seventy subjects were included in the analysis: 51 % were male, average age (±SD) was 55.3 ± 13.7 years, and body mass index was 43.7 ± 10.4 kg/m2. OSAHS was generally severe (apnea-hypopnea index (AHI) 52.8 ± 37.3 event/h). Mean CPAP setting during in-laboratory titration was 11.1 ± 3.1 cm H2O and during the first night of hospitalization was 9.5 ± 2.8 cm H2O (p < 0.0001). Of 170 subjects, only 71 (42 %) received the correct laboratory-derived CPAP setting on the first night of hospitalization. In a multivariable logistic regression analysis, higher body mass index (BMI), lower CPAP level determined during PSG, and shorter latency (months) between PSG and hospitalization were associated with receiving the correct CPAP setting during the first night of hospitalization: Each 1 kg/m2 increase in BMI was associated with a 7 % increase odds of receiving the correct CPAP setting during the first night of hospitalization (OR 1.07, 95 % CI 1.02-1.12), while each 1 cm H2O increase in CPAP during PSG and each 1 month longer latency between PSG and hospitalization was associated with a 15 and 7 %, respectively, decrease in the odds of receiving the correct CPAP setting during the first night of hospitalization (CPAP OR 0.85, 95 % CI 0.74-0.97 and latency OR 0.93, 95 % CI 0.90-0.97). There was no in-hospital mortality, and correct CPAP settings did not affect hospital length of stay.
Conclusions:
Among patients admitted to the hospital, a correct, laboratory-derived CPAP setting is infrequently prescribed during the first night of hospitalization. Predictors for correctly ordering CPAP include latency from the time of in-laboratory CPAP titration, BMI, and laboratory-derived CPAP level.
More Related Videos
07:54Drug-Induced Sleep Endoscopy DISE with Target Controlled Infusion TCI and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
04:53Author Spotlight: Traditional Chinese Medicine for Sleep Disorders in Acute COPD — A Safe, Cost-Effective Approach
Published on: October 18, 2024
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Sleep Apnea
The condition is more prevalent among...
Mechanical Ventilation I: Indication and Settings
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...