Jove
Visualize
Contact Us

Related Concept Videos

Multimachine Stability01:25

Multimachine Stability

602
Multimachine stability analysis is crucial for understanding the dynamics and stability of power systems with multiple synchronous machines. The objective is to solve the swing equations for a network of M machines connected to an N-bus power system.
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
602
Pole and System Stability01:24

Pole and System Stability

1.2K
The transfer function is a fundamental concept representing the ratio of two polynomials. The numerator and denominator encapsulate the system's dynamics. The zeros and poles of this transfer function are critical in determining the system's behavior and stability.
Simple poles are unique roots of the denominator polynomial. Each simple pole corresponds to a distinct solution to the system's characteristic equation, typically resulting in exponential decay terms in the system's...
1.2K
Control System Problem01:21

Control System Problem

475
In an open-loop system, such as a basic thermostat, the poles of the transfer function influence the system's response but do not determine its stability. However, when feedback is introduced to form a closed-loop system, such as an advanced thermostat that adjusts heating based on room temperature, stability is governed by the new poles of the closed-loop transfer function.
When forming a closed-loop system, issues can arise if the poles cross into the unstable region, leading to potential...
475
Transient and Steady-state Response01:24

Transient and Steady-state Response

618
In control systems, test signals are essential for evaluating performance under various conditions. The ramp function is effective for systems undergoing gradual changes, while the step function is suitable for assessing systems facing sudden disturbances. For systems subjected to shock inputs, the impulse function is the most appropriate test signal.
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state...
618
Routh-Hurwitz Criterion I01:15

Routh-Hurwitz Criterion I

642
Consider an electrical power grid, where stability is essential to prevent blackouts. The Routh-Hurwitz criterion is a valuable tool for assessing system stability under varying load conditions or faults. By analyzing the closed-loop transfer function, the Routh-Hurwitz criterion helps determine whether the system remains stable.
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...
642
Load-frequency control01:28

Load-frequency control

732
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
732

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Multi-purpose droop controllers incorporating a passivity-based stabilizer for unified control of electronically interfaced distributed generators including primary source dynamics.

ISA transactionsยท2016
See all related articles
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: Mar 12, 2026

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
06:04

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator

Published on: February 14, 2025

1.1K

A robust nonlinear stabilizer as a controller for improving transient stability in micro-grids.

Seyed Mohammad Azimi1, Saeed Afsharnia2

  • 1(a)School of Electrical and Computer Engineering, College of Engineering, University of Tehran, Tehran 1439957131, Iran; (b)Department of Electrical Engineering, Hamedan University of Technology, Hamedan 65155, Iran.

ISA Transactions
|November 5, 2016
PubMed
Summary
This summary is machine-generated.

This study introduces a novel parametric-Lyapunov stabilizer to enhance micro-grid (MG) transient stability. The stabilizer uses local information for improved performance in all operational modes.

Keywords:
Parametric-LyapunovRobustnessStabilizerTransient stability

More Related Videos

Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators
11:44

Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators

Published on: August 15, 2014

10.8K

Related Experiment Videos

Last Updated: Mar 12, 2026

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
06:04

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator

Published on: February 14, 2025

1.1K
Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators
11:44

Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators

Published on: August 15, 2014

10.8K

Area of Science:

  • Electrical Engineering
  • Control Systems
  • Power Systems

Background:

  • Micro-grids (MGs) require robust control strategies for stable operation during various modes and transitions.
  • Electronically-interfaced distributed resources (EI-DRs) are key components in modern MGs, necessitating effective stabilization techniques.
  • Transient stability is crucial for MGs, especially concerning frequency deviations during operational changes.

Purpose of the Study:

  • To design and validate a parametric-Lyapunov stabilizer for improving micro-grid transient stability.
  • To develop a unified control configuration for EI-DRs applicable across grid-connected, islanded, and transition modes.
  • To ensure the stabilizer's effectiveness, robustness, and implementation simplicity.

Main Methods:

  • A parametric-Lyapunov approach is employed for stabilizer design.
  • A novel parametric-Lyapunov function is introduced to enhance damping of transition transients.
  • The stabilizer is designed to operate using only local information, eliminating communication link requirements.
  • Mathematical proofs and time-domain simulations are used for verification and analysis.

Main Results:

  • The proposed stabilizer demonstrates improved damping of system transition transients.
  • Robustness of the stabilizer is verified through simulations and mathematical analysis.
  • An ultimate bound for frequency transition transients is derived.
  • The stabilizer's effectiveness is validated on a multi-resource MG and compared to existing methods.

Conclusions:

  • The parametric-Lyapunov stabilizer offers an effective and simple solution for enhancing micro-grid transient stability.
  • The stabilizer's reliance on local information and unified control configuration simplifies implementation and enhances applicability.
  • The proposed method provides a robust approach to managing frequency transients and resource delays in MGs.