Related Experiment Video
Updated: Mar 12, 2026

Point-Of-Care Ultrasound Screening for Proximal Lower Extremity Deep Venous Thrombosis
Published on: February 10, 2023
A clinical decision rule and D-dimer testing to rule out upper extremity deep vein thrombosis in high-risk patients
Nick van Es1, Suzanne M Bleker1, Marcello Di Nisio2
1Department of Vascular Medicine, Academic Medical Center, Amsterdam, The Netherlands.
Introduction:
In a management study, a diagnostic algorithm consisting of a clinical decision rule, D-dimer, and ultrasonography was shown to safely exclude upper extremity deep vein thrombosis (UEDVT). Efficiency may be lower in high-risk subgroups: those with a central venous catheter or pacemaker, inpatients, cancer, and elderly patients.
Methods:
Data of 406 patients with suspected UEDVT enrolled in a prospective management study were used for the present analysis. The aim was to evaluate the efficiency of the algorithm in subgroups, defined as the proportion of patients in whom imaging could be safely withheld based on the combination of a decision rule result indicating "UEDVT unlikely" and a normal D-dimer result.
Results:
The strategy excluded UEDVT in 87 of 406 patients (21%); ultrasonography was withheld in these patients and none developed UEDVT during 3months of follow-up. In contrast, ultrasonography could be withheld in only 4 of 92 patients with a catheter or pacemaker (4.3%; 95% CI: 1.7% to 11%) and in 4 of 83 inpatients (4.8%; 95% CI: 1.9% to 12%). The efficiency was 11% in patients with cancer and 13% in those older than 75years.
Conclusion:
Although the combination of a decision rule and D-dimer testing is safe in excluding UEDVT in the overall population of patients with suspected UEDVT, its efficiency appears limited in some subgroups, in particular those with a central venous catheter or pacemaker, and inpatients.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Venous Thrombosis III: Interprofessional Care
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Venous Thrombosis IV: Nursing Management
Pulmonary Embolism III: Nursing Management
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...