Does Small Size Matter With Continuous Flow Devices?: Analysis of the INTERMACS Database of Adults With BSA ≤1.5 m2
Farhan Zafar1, Chet R Villa1, David L Morales1
1Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio.
Objectives:
This study investigated how small patient size affects clinical outcomes in patients implanted with a continuous flow left ventricular assist device (CFLVAD).
Background:
The development of smaller CFLVADs has allowed ventricular assist device (VAD) use in anatomically smaller patients; however, limited outcome data exist regarding CFLVAD use in patients with a body surface area (BSA) ≤1.5 m2.
Methods:
All CFLVAD patients entered in the Interagency Registry for Mechanically Assisted Circulatory Support registry April 2008 to September 2013 and with BSA data were included. Biventricular VAD patients were excluded. Patient characteristics and clinical outcomes were compared between patients with BSA ≤1.5 m2 (small patients) and those >1.5 m2.
Results:
Of 10,813 CFLVAD recipients, 231 had a BSA ≤1.5 m2. Small patients were more commonly female patients (68% vs. 20%; p < 0.01), Hispanic (10% vs. 6%; p < 0.03), and on intravenous inotropes (88% vs. 80%; p < 0.01). Small patients had higher bleeding (p < 0.01) and driveline infection (p < 0.01) rates, while exhibiting lower rates of right heart failure (p < 0.01) and renal dysfunction (p < 0.01). Device malfunction rate (p > 0.05), overall survival (p > 0.05), and 1-year competing outcomes (p > 0.05) were similar between BSA groups.
Conclusions:
Patients with a BSA ≤1.5 m2 supported with a CFLVAD have similar survival to larger patients. These data support the use of CFLVAD in anatomically small patients.
Related Concept Videos
Blood Flow
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Capillary Beds
Capillaries connect arterioles, small branches of arteries, to venules,...
Continuity Equation
The mass flow rate is expressed as:
External and Internal Respiration
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...


