The noise factor of receiver coil matching networks in MRI

Xueming Cao1, Elmar Fischer1, Oliver Gruschke2

  • 1Dept. of Radiology, Medical Physics, University Medical Center Freiburg, Freiburg, Germany.

Related Concept Videos

NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
1.1K
Mesh Analysis for AC Circuits01:12

Mesh Analysis for AC Circuits

In the domain of radio communication, the significance of impedance matching must be considered. It is crucial to ensure the efficient transmission of signals between radio transmitters and receivers. Achieving this balance involves using impedance-matching circuits, with one fundamental configuration comprising a resistor, capacitor, and inductor.
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...
755
Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
10.1K
Atomic Nuclei: Magnetic Resonance01:05

Atomic Nuclei: Magnetic Resonance

The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
1.3K
¹H NMR Signal Multiplicity: Splitting Patterns01:13

¹H NMR Signal Multiplicity: Splitting Patterns

When protons A and X are coupled, their nuclear spin energy levels are slightly modified. This is because the energy required to excite proton A to a spin state parallel to proton X is slightly different from the energy required for it to become anti-parallel to spin X. Consequently, there are two possible excitation frequencies for A (A1 and A2), depending on the spin state of X, and vice versa. The mutual nature of coupling implies that the difference between frequencies A1 and A2, indicated...
7.9K
NMR Spectroscopy: Spin–Spin Coupling01:08

NMR Spectroscopy: Spin–Spin Coupling

The spin state of an NMR-active nucleus can have a slight effect on its immediate electronic environment. This effect propagates through the intervening bonds and affects the electronic environments of NMR-active nuclei up to three bonds away; occasionally, even farther. This phenomenon is called spin–spin coupling or J-coupling. Coupling interactions are mutual and result in small changes in the absorption frequencies of both nuclei involved. While nuclei of the same element are involved...
3.6K