Losses in tissue associated with finite amplitude ultrasound transmission
F J Fry1, K A Dines, C R Reilly
1Indianapolis Center for Advanced Research, Inc., IN 46204.
Abstract:
The ultrasonic absorption coefficient of freshly-excised rat liver is measured as a function of intensity in a 1 MHz focused field. The 7 cm diameter source has a geometric focus of 20 cm and a half-intensity linear focal beamwidth of 4.65 mm. Free-field harmonic content and radiation force measurements within the focal region indicate that quasilinear shock (sigma = 1) is attained in the intensity range of 225 W cm-2 to 275 W cm-2 SPTP intensity. Radiometric measurements of focal beamwidth and intensity response (focal intensity versus transducer input voltage squared) demonstrated beam narrowing up to 700 W cm-2 and focal intensities greater than would be expected from linear theory. This nonlinear acoustic field is employed to measure the absorption coefficient of liver at the beam focus. The pressure absorption coefficient, measured via the transient thermoelectric technique, was 0.038 Np cm-1 at low intensities (below 100 W cm-2 SPTP) and rose to approximately 0.117 Np cm-1 at 750 W cm-2 SPTP intensity. The absorption predicted using spherically converging beam theory is in agreement with the experimental data at the lower (below 200 W cm-2) and the higher (above 650 W cm-2) intensities. Gaussian theory provided a poor fit to the experimental data even after deficiencies in the model were considered.
More Related Videos
07:38Real-time Monitoring of High Intensity Focused Ultrasound (HIFU) Ablation of In Vitro Canine Livers Using Harmonic Motion Imaging for Focused Ultrasound (HMIFU)
Published on: November 3, 2015
08:39Multiplexing Focused Ultrasound Stimulation with Fluorescence Microscopy
Published on: January 7, 2019
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Lossless Lines
Boundary Conditions: Lossless Lines
At the receiving end, the boundary condition states that the voltage equals the product of the receiving-end impedance and current. This relationship is expressed as a function of the incident and...
Lossy Lines and Overvoltages
Attenuation
When constant series resistance and shunt conductance are present, voltage and current equations are modified. The propagation constant indicates that voltage and current waves consist of both forward and backward traveling components. These waves attenuate as they propagate, with the attenuation factor related to the resistance and conductance. In a...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...