The Use of Stepper Motor-Controlled Proportional Valve for Fio2 Calculation in the Ventilator and its Control with

Adem Gölcük1, İnan Güler2

  • 1Vocational School of Technical Sciences, Department of Computer Technologies, Karamanoğlu Mehmetbey University, Karaman, Turkey. ademgolcuk@kmu.edu.tr.

Related Concept Videos

Open and closed-loop control systems01:17

Open and closed-loop control systems

Control systems are foundational elements in automation and engineering. They are broadly categorized into open-loop and closed-loop systems. These classifications hinge on the presence or absence of feedback mechanisms, significantly influencing the system's performance, complexity, and application.
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
1.9K
PID Controller01:19

PID Controller

Proportional-Integral-Derivative (PID) controllers are widely used in various control systems to enhance stability and performance. In a thermostat, it adjusts heating or cooling based on the temperature difference between the actual and desired levels. They are often used in automotive speed systems, effectively managing sudden speed changes while maintaining a constant speed under varying conditions. On the other hand, PI controllers, commonly employed in voltage regulation, enhance stability...
855
Ventilatory Modes01:14

Ventilatory Modes

Mechanical ventilators are life-saving devices that support or replace spontaneous breathing. They deliver breaths to patients through varying methods known as ventilator modes. Understanding these modes is critical for healthcare providers managing patients with respiratory failure.
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
1.9K
Mechanical Ventilation II: Invasive Ventilation01:23

Mechanical Ventilation II: Invasive Ventilation

Ventilators are essential medical equipment used to aid patients with respiratory difficulties. Their primary function is to assist or replace spontaneous breathing by providing mechanical ventilation. There are two general classes of mechanical ventilators: negative-pressure and positive-pressure ventilators.
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
931
Motor Unit Stimulation01:20

Motor Unit Stimulation

When the neuron of a motor unit fires an action potential, it triggers a series of events, leading to a twitch contraction in the muscle fibers. The process of excitation-contraction coupling is crucial in relaying the action potential to the muscle fibers.
The latent period of contraction marks the onset of excitation-contraction coupling, when the action potential propagates across the sarcolemma, preparing the muscle fibers for contraction. As the fibers enter the contraction phase, the...
4.3K
Potentiometer01:30

Potentiometer

Voltage and current measurements using a standard voltmeter and ammeter alter the circuit being measured either by drawing or resisting the current flow, which introduces uncertainties in the measurements. Null measurements balance the voltages so that no current flows through the measuring device and, therefore, no alterations occur in the measured circuit.
Suppose the emf of a battery needs to be measured. If the battery is directly connected to a standard voltmeter, the measured quantity is...
2.3K